16. Place the timing valve knob (122) over the needle
valve (117), with the "0" lined up with the marker on
the label (121). Tighten the hex set screws (123).
121
F
. 26 Align timing valve knob with label
IG
17. Reinstall the drive piston (107) in the bottom of the
upper housing (110).
NOTE: Do not apply grease to the dynamic seals (105 &
108). They are designed to operate without grease.
18. Reinstall the seal cartridges (see F
order of the seals (105) and o-rings (124)) into the
lower housing (101). Apply a thin coat of grease on
3A4386E
Marker
122
. 23 for the
IG
the housing lead-in (130) to ease installation and
ensure that the seals are not damaged.
Lead-in
F
. 27 Reinstall seal cartridges and spool
IG
19. Reinstall the spool (103) carefully through the seal
cartridge components.
Repair
103
125
102 (w/105 & 124)
130
35