Calibrate Chemical Dosage

1. Begin the process by setting the timing valve (22) to
an estimated setting of the flow rate. See Baseline
Chemical Dosage Settings, page 20, for tables of
cycles per minute (CPM), and corresponding gal-
lons per day (GPD) and liters per day (LPD).
122
22
F
. 4 Calibrate Chemical Dosage
IG
2. Follow the instructions provided with your calibration
gauge in conjunction with the Baseline Chemical
Dosage Settings on page 20.
3. Adjust the timing valve (22) accordingly after the
test is performed. Turning the knob (122)
counter-clockwise will increase the pump flow rate,
while turning the knob clockwise will decrease the
flow.
4. Repeat the test procedure to verify your changes.
Repeat as necessary until the desired flow rate is
achieved.
3A4386E
Stroke Adjustment
This pump has infinite stroke adjustment between full
and 1/4 stroke, and has four marked stroke adjustment
positions.
21
1/2 stroke
21
(1/2", 13 mm)
Full (1", 25 mm)
F
. 5 Stroke adjustment settings
IG
To increase the stroke length, turn the stroke adjust-
ment knob (21) counter-clockwise.
To decrease the stroke length, turn the stroke
adjustment knob (21) clockwise.
Operation
1/4 stroke
(1/4", 6 mm)
3/4 stroke
(3/4", 19 mm)