Required Installation Tools (Not Supplied); Selecting The Installation Location; Indoor Clearances; Outdoor Parts - Johnson Controls DHPM09NWM42Q1 Installation Manual

Lx ductless multi zone heat pumps
Hide thumbs Also See for DHPM09NWM42Q1:
Table of Contents

Advertisement

ASSEMBLED OUTDOOR UNIT
The assembled outdoor unit will include the following items which are
located with the unit:
TABLE 2: Outdoor Parts
Auxiliary drain
hole plugs
(heat pump only)
Drain plug
(heat pump only)
3/8" to 1/2" Line Adapter
Provided to be used with 24K,
30K, & 42K outdoor units when
combined with 18K indoor units.
SECTION IV: REQUIRED INSTALLATION
TOOLS (NOT SUPPLIED)
1. Gauge manifold
2. Electronic balance for refrigerant charging
3. Phillips head screwdriver
4. Knife or wire stripper
5. Carpenters level
6. Hammer
7. Drill
8. Tube cutter
9. Tube flaring tool
10. Torque wrench
11. Adjustable wrench
12. Reamer (for de-burring)
13. Vacuum pump (For R410A)
14. Gas leakage detector
MATCHED UNIT COMBINATIONS
TABLE 3: Multi Zone Matchup
OUTDOOR UNIT
DHMF18CMM42Q1
DHMF18CMM42Q1
DHMF24CMM42Q1
DHMF24CMM42Q1
DHMF24CMM42Q1
DHMF30CMM42Q1
DHMF30CMM42Q1
DHMF42CMM42Q1
Johnson Controls Unitary Products
1 - 3
1
2
INDOOR UNITS
(2) DHPM09NWM42Q1
(1) DHPM09NWM42Q1 +
(1) DHPM12NWM42Q1
(2) DHPM09NWM42Q1 +
(1) DHPM12NWM42Q1
(3) DHPM09NWM42Q1
(1) DHPM09NWM42Q1 +
(2) DHPM12NWM42Q1
(4) DHPM09NWM42Q1
(1) DHPM09NWM42Q1 +
(1) DHPM12NWM42Q1 +
(1) DHPM18NWM42Q1
(2) DHPM09NWM42Q1 +
(2) DHPM12NWM42Q1
SECTION V: SELECTING THE
INSTALLATION LOCATION
INDOOR UNIT (SEE FIGURE 2 FOR INSTALLATION
DIMENSIONS)
1. Install the unit securely in a place that can bear the weight and
vibration of the unit.
2. Select a location where the condensate can be easily drained out.
3. Install in a location where there is enough space to access the unit
for routine maintenance (air filter can be removed for cleaning or
replacement).
4. Install where airflow is not blocked.
5. Install in a location for optimized cold or warm air distribution.
6. Install in a location that's not exposed to direct sunlight.
7. Install in a location that's at least 3 ft away from a TV and radio to
avoid possible interferences with the operation of the air condi-
tioner/heat pump.
8. Install in a location that's at least 3 feet away from fluorescent and
incandescent lights to avoid interference with the remote control.
A
D
B
Reference
A
Clearance between unit and ceiling
B
Clearance between unit and floor
C / D
Clearance to the right and left of the unit
FIGURE 1: Indoor Clearances
REMOTE CONTROL
1. Keep the remote control where it is convenient to operate and eas-
ily visible.
2. Keep the remote control away from children.
3. When using the I FEEL feature, select a location for the remote
control that's about 4 ft. above the floor.
NOTICE
In rooms where inverter type fluorescent lamps are used, the signal
from the wireless remote controller may not be received.
OUTDOOR UNIT (SEE FIGURE 3 FOR
INSTALLATION DIMENSIONS)
1. Some localities are adopting sound ordinances based on the unit's
sound level registered from the adjacent property, not from the
property where the unit is installed. Install the unit as far as possible
from the property line.
2. When possible, do not install the unit directly outside a window.
Glass has a very high level of sound transmission. For proper
placement of unit in relation to a window see Figure 3.
3. Install unit level or, if on a slope, maintain slope tolerance of 2
degrees (or 2 inches per 5 feet) away from building structure.
898150-UIM-B-0113
C
Required
Location
Clearance
6 inches
6 inches
6 feet
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents