Shipping And Packaging List; Indoor Parts - Johnson Controls DHPM09NWM42Q1 Installation Manual

Lx ductless multi zone heat pumps
Hide thumbs Also See for DHPM09NWM42Q1:
Table of Contents

Advertisement

898150-UIM-B-0113
Improper or incomplete installation, adjustment, alteration, service or
maintenance could cause personal injury, loss of life, or damage to
property. Installation and service must be performed by a licensed
professional dealer or contractor.
• The unit should be installed by an authorized dealer or contractor according to local codes and in compliance with this manual.
• Follow the instructions detailed in the installation manual.
• Confirm proper insulating, taping and bundling of refrigeration lines, main power lines and drain line (see procedure starting on Page 14).
• Perform electrical work according to the installation manual and local codes. Be sure to use a dedicated circuit (do not connect other electrical
appliances to the same circuit).
• Ground the unit correctly - do not connect the ground wire to a gas pipe, lightning rod, telephone ground or water pipe. Defective grounding
could cause equipment malfunction and/or electric shock.
• Do not damage the wires.
• Shut off the main power when setting up the indoor P.C. board or wiring.
• Use the specified wires to securely connect the indoor and outdoor units. Attach the wires firmly and avoid applying to much pressure to the ter-
minal block - Stranded wire is highly recommended to connect the outdoor unit to the indoor unit. The stranded wire ensures proper system
communication and operation.
• Do not install the unit in a place where flammable gas may leak.
• Do not use intermediate connection of the power cord or a power extension cord.
• The refrigerant temperature tends to get very high. Make sure you keep the electrical wires away from the copper tube.
• Use the parts provided or specified parts for the installation work.
• Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit.
• When installing or relocating the unit, make sure that no substance other than the specified refrigerant (R410A) enters the refrigerant circuit.
• Do not discharge the refrigerant into the atmosphere. Check that the refrigerant gas does not leak after installation has been completed. If refrig-
erant leaks during installation, ventilate the room.
• Use appropriate tools and piping materials for installation - the pressure of R410A is 1.6 times higher than R22. Not using the appropriate tools
and materials, or improper installation could cause the pipes to burst causing an injury.
• When pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes.
• When installing the unit, securely connect the refrigerant pipes before starting the compressor.
• Fasten a flare nut with a torque wrench as specified in this manual.
• Perform the drainage/piping work securely according to the installation manual - If there is defect in the drainage/piping work, water could drip
from the unit, and damage household items.
• Do not install the outdoor unit where small animals may live. Keep the area around the unit clean
• The included remote control could be shipped in various locations in the unit packaging. Locate remote control before discarding packaging (i.e.
bag assembly, styrofoam, etc.). Unit cannot be properly operated without the included remote control.
SECTION III: SHIPPING AND PACKAGING LIST
Check the unit components for shipping damage. If you see any damage, contact the carrier immediately.
ASSEMBLED INDOOR UNIT
The assembled indoor unit will include the following items:
TABLE 1: Indoor Parts
Remote Control
Batteries (AAA)
Wall mounting bracket
screws
Foam tube insulation
(for condensate line
attached to indoor unit)
2
The Clean Air Act of 1990 bans the intentional venting of refrigerant
(CFCs, HCFCs and HFCs) as of July 1, 1992. Approved methods of
recovery, recycling or reclaiming must be followed. Fines and/or
incarceration may be levied for noncompliance.
Flare nut 1/4" for small
line on all size units
1
except 30K which
uses 5/8".
Cable routing guide
with mounting
2
hardware (18 - 24 kBtu
systems only)
09, 12 & 18 kBtu (5)
Installation Manual
24K kBtu (10)
User's Information
1
Manual
Johnson Controls Unitary Products
1
1
1
1