Summary of Contents for Moxa Technologies EDS-2005-EL Series
Page 1
ED S- 2 0 0 5 - EL/ ELP Se r ie s Qu ick I n st a lla t ion Gu ide M ox a Et h e r D e vice Sw it ch Ve r sion 1 .0 , Oct obe r 2 0 1 9 Te chnica l Suppor t Cont a ct I nfor m a t ion w w w .m ox a .com / suppor t Moxa Am ericas:...
Ove r vie w The EDS- 2005- EL/ ELP Series has a 5- port com binat ion t o sim plify net work expansion. There are t wo housing t ypes available for t he user t o select depending on t he requirem ent s of t heir applicat ion. The ELP has a plast ic housing and t he EL has a m et al housing.
Page 3
Fe a t u r e s H igh Pe r for m a nce N e t w ork Sw it ching Te chnology • 10/ 100BaseT( X) aut o- negot iat ion speed, full/ half duplex m ode, aut o MDI / MDI - X connect ion.
Page 4
Pa n e l La yout of ED S- 2 0 0 5 - EL/ ED S- 2 0 0 5 - ELP Chassis ground screw Term inal block for power input DI P swit ch Power LED 10/ 100 BaseT( X) Port 10/ 100 BaseT( X) Port LED Port num ber Model nam e...
Page 5
M ou n t in g D im e n sion s ED S- 2 0 0 5 - EL Se r ie s ED S- 2 0 0 5 - ELP Se r ie s - 5 -...
Page 6
D I N - r a il M ou n t in g When shipped, t he DI N- rail m ount ing kit is fixed t o t he back panel of t he EDS. Mount t he EDS on t he corrosion- free m ount ing rail t hat adheres t o t he EN 60715 st andard.
Page 7
W a ll M ou n t in g ( opt ion a l) For som e applicat ions, you will find it convenient t o m ount EDS on t he wall, as illust rat ed below. There are t wo opt ions for inst allat ion: The first opt ion is t o hook t he EDS DI N- rail lat ch on t he opening of t he wall m ount kit ( see pict ure above) and t hen m ount t he wall- m ount kit on t he wall wit h screws.
Page 8
W ir in g Re qu ir e m e n t s W ARN I N G Do not disconnect m odules or wires unless t he power supply has been swit ched off or t he area is known t o be non- hazardous.
Page 9
Gr ou n din g M ox a Et h e r D e vice Sw it ch Grounding and wire rout ing help lim it t he effect s of noise due t o elect rom agnet ic int erference ( EMI ) . Run t he ground connect ion from t he ground screw t o t he grounding surface prior t o connect ing devices.
Page 10
ATTEN TI ON One individual conduct or in a clam ping point wit h 28- 14 AWG wire size, and a t orque value of 1.7 lb- in should be used. Com m u n ica t ion Con n e ct ion s The EDS- 2005- EL/ ELP m odels have 10/ 100BaseT( X) Et hernet port s.
Page 11
D I P Sw it ch Se t t in gs D I P Sw it ch Se t t ing D e scr ipt ion Qualit y of Enable t he Qualit y of Service t o handle Service ( QoS) packet priorit ies in four WRR queues.
Page 12
D u a l Spe e d Fu n ct ion a lit y a n d Sw it ch in g The EDS’s 10/ 100 Mbps RJ45 swit ch port aut o negot iat es wit h t he connect ed device for t he fast est dat a t ransm ission rat e support ed by bot h devices.
Page 13
Spe cifica t ion s Te chnology St andards I EEE 802.3 for 10BaseT, I EEE 802.3u for 100BaseT( X) and 100Base FX, I EEE 802.1p for Class of Service Flow Cont rol I EEE 802.3x flow cont rol, back pressure flow cont rol I nt e r fa ce RJ45 Port s...
Page 14
Shock I EC60068- 2- 27 Free Fall I EC60068- 2- 32 Vibrat ion I EC60068- 2- 6 W a r r a nt y 5 years Address of FL. 4, No.135, Lane 235, Baoqiao Road, Xindian Manufact urer Dist rict , New Taipei Cit y, Taiwan R.O.C. - 14 -...