send error notification. Control
Key Output.
0x33 - Sends start/end sentinel
and only sends account number
on Track 2, does not send error
notification. Control Key
Output.
0x34 - Not send start/end
sentinel and send all data on
Track 2, send error
notification(default). Control
Key Output.
0x35 - Sends start/end
sentinel, all data on Track 2, and
error notification. Control Key
Output.
0x36 – Does not send start/end
sentinel and only sends account
number on Track 2. Also sends
error notification. Control Key
Output.
0x37 - Send start/end sentinel
and only send account number
on Track 2, send error
notification. Control Key
Output.
0x38 – Does not send start/end
sentinel and sends all data on
Track 2, no error notification.
Alt Key Output.
0x39 - Sends start/end sentinel
and sends all data on Track 2,
not sends error notification. Alt
Key Output.
0x3a – Does not send start/end
sentinel, only sends account
number on Track 2, and does
not send error notification. Alt
Key Output.
0x3b - Send start/end sentinel
and only send account number
on Track 2, not send error
notification. Alt Key Output.
0x3c - Not send start/end
sentinel and send all data on
Track 2, send error
notification(default). Alt Key
Output.
0x3d - Sends start/end
sentinel, sends all data on Track