Dimensions And Clearances; Mantel Clearances - Valor Portrait Ledge 569 Series Installation Manual

Hide thumbs Also See for Portrait Ledge 569 Series:
Table of Contents

Advertisement

Available languages

Available languages

Dimensions & Clearances
27-3/8" (696 mm)
31-1/8" (790 mm)
22-1/2" (572 mm)
2"
(51 mm)
12-3/4"
3-5/8"
(324 mm)
(92 mm)
to
7-1/8"
surface
(181 mm)
of wall
finish
2" (51 mm) sidewall
minimum clearance

Mantel Clearances

0–6"
Mantel Depth 'A'
(0–152 mm)
Mantel Height 'B'
(102 mm)
20" (508 mm)
6-5/8" (168 mm) dia.
cement board
and drywall
thickness:
1/2" (13 mm)
wall finish thickness
over top of drywall:
max 1" (25 mm),
1/2" (13 mm)
when using 570 Plate
8"
10"
(203 mm)
(254 mm)
4"
8"
10"
(203 mm)
(254 mm)
Cement board
570 Finishing Plate
sold separately
Min. 36" (0.9 m) to
combustible materials
1/2" (13 mm) min.
under bottom of
trim for air gap
bottom of trim
3-5/16" (84 mm)
bottom of 570
570 plate thickness: 1/2" (13 mm)
12"
(305 mm)
12"
(305 mm)
4" (102 mm) between
bottom of engine and
bottom of 570 plate
90°
47-15/16" (1216.9 mm)
Combustible
mantel
Face of
cement
B
board/
drywall
Side View
center
of vent
11/16" (17 mm) between
bottom of engine and
bottom of trim
Face of
wall studs
A
3