9. Propulsion System and Water Quality System Troubleshooting
Symptom
Propulsion System
Wont Turn On
No Swim Current when
propulsion system pump is on
15
15
Possible Cause
1.) 25 amp fuse blown inside the
heater controller
2.) No power to pump receptacle
on the heater controller
3.) Propulsion system pump is not plugged in
4.) Damaged Key 1 button on keypad display
1.) Water level is to low
2.) Slide valve is in the closed position
3.) Air trapped in plumbing
Solution
1.) Check for continuity on the fuse and Pump
replace if necessary
2.) 25 amp fuse may be blown inside heater
controller . If fuse is not blown, turn off
breaker for 5 minutes and reset . If still no
voltage to pump receptacle, replace heater
controller .
3.) Plug pump in. Plug must "lock" into place
4.) If pump 1 icon does not appear when
pressing Key 1, replace the keypad
1.) Add water to pool. The water level
should cover the honeycomb grill on
the front of the propulsion system
housing .
2.) Open slide valve
3.) With the propulsion system running on high
speed, slowly unthread the air plug at the top
of the pump housing to allow air to escape .
Need help?