Summary of Contents for Zeiss AURA

  • Page 1 AURA ® handheld NIR User Manual...
  • Page 2 + 49 3641 64-2485 Internet www.zeiss.com/spectroscopy Publication number: EN_40_070_0004I UM AURA ® handheld NIR – 2289-971 and 2289-955 / E | 2020-03 1st edition March 2020 Subject to technical changes AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 3: Table Of Contents

    AURA handheld NIR with slanted handle 3.2.1 Functional elements 3.2.2 Controls and indicators 3.2.3 Interfaces 3.2.4 Dimensions 4 Technical description ������������������������������������������������������������23 Function description Specifications ZEISS InProcess software WiFi settings 5 Application note �������������������������������������������������������������������29 User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 4 Fig. 9 InProcess software – welcome screen ........27 Fig. 10 WiFi setting – connect to network........27 Fig. 11 WiFi setting – create access point ........28 Fig. 12 Exchanging the battery pack ..........37 AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 5: Safety Instructions

    AURA handheld NIR Safety instructions Safety instructions The AURA handheld NIR has been designed and tested in compliance with the Radio Equipment Directive (RED) 2014/53/EU due to the built-in WiFi adapter and left the factory in a faultless state. The RED-Directive includes the general requirements according to Safety and Electromagnetic Compatibility EMC.
  • Page 6: Used Symbols And Signal Words

    The symbols below are used in this user manual to indicate safety relevant or helpful information: Attention Warning of possible property damage Note Read the User Manual Note Important general note Note Important note about environmental protection AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 7: General Safety Instructions

    Warning and note signs must not be removed and must always be in a legible condition. Please note: • The AURA handheld NIR must not be started if it is damaged or in a wet condition. • Do not open the system.
  • Page 8: Environmental Management

    The product must not get into domestic waste nor be disposed of via municipal waste disposal facilities. On resale of the product, the seller is obligated to inform the buyer that the product must be disposed of properly. AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 9: Storage And Transport

    For air transport, follow the latest internationally applicable regulations for the transport of Li-ion batteries� The AURA handheld NIR with standard handle (2289-971) works with the Standard Li-ion Smart Battery Pack RRC 2054 by RRC power solutions. The AURA handheld NIR with slanted handle (2289-955) works with the Standard Li-ion Smart Battery Pack RRC 2040-2 by RRC power solutions.
  • Page 10: Wifi

    — Russia, Belorussia, — Kazakhstan South Africa ICASA — South Korea — Australia and — New Zealand Taiwan — Singapore IMDA — Israel — Tab. 1 WiFi – national certificates AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 11 WiFi adapter� The safe range of operation depends on a free line of sight and the environmental conditions� The manufacturer assumes a safe range of operation of up to 5 m distance� User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 12: Basic Information

    The following must be checked before the system is started: • The user manual must be read carefully before the system is used. • The AURA handheld NIR must not be wet or damaged. The user manual contains a description of the hardware and how to operate the AURA handheld NIR.
  • Page 13: Intended Use

    It is also used for displaying and storing results and related data. The AURA handheld NIR may only be used for its intended purpose as described. Any other use is contrary to regulations. The operator will assume liability for any resulting damage.
  • Page 14: Connection And Environmental Parameters

    39 in this manual, no maintenance or repair of the instrument may be undertaken. Repairs may only be carried out by ZEISS service staff or persons explicitly authorized by ZEISS. In case of any malfunction of the device, contact the customer service department at Carl Zeiss Spectroscopy GmbH (service.spectroscopy@zeiss.com).
  • Page 15: System Overview

    “7�2 Accessories” on page 39� 3.1.1 Functional elements Fig. 1 Functional elements Battery pack (in the battery compartment) Handle (with “Start measurement button”) Measurement window Touchscreen Wrist strap User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 16: Controls And Indicators

    • green, constant: sensor is ready • green, flashing: sensor is measuring • yellow: internal referencing in progress • red: an error occurred • Power ON button AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 17: Interfaces

    19 V DC in (from Battery charger RRC-SMB-UBC) The device is supplied with interface covers that can be disposed of. The interfaces are dust-tight and water-protected and can be used without covers. User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 18: Dimensions

    AURA handheld NIR System overview 3.1.4 Dimensions ø 40 Fig. 4 Dimensions Rear Display side Front AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 19: Aura Handheld Nir With Slanted Handle

    “7�2 Accessories” on page 39� 3.2.1 Functional elements Fig. 5 Functional elements Battery pack (in the battery compartment) Handle (with “Start measurement button”) Measurement window Touchscreen Wrist strap User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 20: Controls And Indicators

    • green, constant: sensor is ready • green, flashing: sensor is measuring • yellow: internal referencing in progress • red: an error occurred • Power ON button AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 21: Interfaces

    19 V DC in (from Battery charger RRC-SMB-UBC) The device is supplied with interface covers that can be disposed of. The interfaces are dust-tight and water-protected and can be used without covers. User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 22: Dimensions

    AURA handheld NIR System overview 3.2.4 Dimensions ø 40 Fig. 8 Dimensions Rear Display side Front AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 23: Technical Description

    Technical description Technical description Function description The AURA handheld NIR has been developed for the most diverse optical measuring applications and consists of a polychromator with a measuring head for diffuse reflection. The front panel includes a sapphire window. The spectrometer features fiber free, high energy illumination and internal referencing.
  • Page 24: Specifications

    (battery pack RRC2040-02) Power supply (external) 19.0 V DC 19.0 V DC Power consumption 24 W 24 W Interfaces Communication Ethernet 1000 MBit/s, Ethernet 1000 MBit/s, 2x USB 2x USB AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 25 Halogen lamp, Halogen lamp, 20,000 h 20,000 h (Exchange by ZEISS service (Exchange by ZEISS service only!) only!) Measuring spot diameter 13.5 mm 13.5 mm Tab. 3 AURA handheld NIR specifications User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 26: Zeiss Inprocess Software

    “Manuals” on the left side and the “InProcess Manual” from the list of manuals� To fully incorporate all AURA handheld NIR features (e.g. system status LED, continuous scan, mutliple single scans or automated internal referencing) please use the “AURA handheld NIR” product templates for new product configurations.
  • Page 27: Wifi Settings

    When logged in as Administrator, select the “System settings” tile on the welcome screen and choose the "WiFi" settings page. The system settings for WiFi define how the AURA handheld NIR is utilized for network communication. Fig. 10 WiFi setting – connect to network...
  • Page 28: Fig. 11 Wifi Setting - Create Access Point

    Technical description Operation mode You can either establish a connection with an existing network or use the AURA handheld NIR to create an access point for other participants, e.g. your laptop. Status Here you see the current status of the network adapter.
  • Page 29: Application Note

    NIR spectrometer for measuring constituents of solid samples in direct contact. It is also used for displaying and storing results and related data. The AURA handheld NIR has a measuring window diameter of 38 mm. Due to the optical layout, a measuring spot of 13.5 mm is realized, which lies in the middle of the measuring window.
  • Page 30 Measuring procedure A measurement is generally triggered by pressing the “Start measurement button” on the handle. The status LED on the back of the AURA handheld NIR changes from green (sensor is ready) to yellow (internal referencing in progress) to green, flashing (sensor is measuring).
  • Page 31 Adapting the AURA product templates The user can modify AURA product templates and do individual changes e.g. in the measurement process by entering sample name dialogs, adapting the number of scans to calculate averages, modifying the result display on the monitor or integrate new NIR calibrations.
  • Page 32 The installation of the corresponding runtime library, a so-called prediction engine, is free of charge, but a license is required and must be purchased to use it. Only the prediction engine GRAMS is preinstalled and free of charge. AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 33: Getting Started

    You can start right away by plugging the charger cable into the socket on the backside of the AURA handheld NIR (see Fig. 3 / 3 or Fig. 7 / 3). Insert a battery pack into the battery compartment of the AURA handheld NIR, until the “Release buttons”...
  • Page 34: Start Measurement

    Depending on the preset measurement process, the following steps show the exemplary interaction of the user with the instrument: 1. Press the “Start measurement button” on the AURA handheld NIR. 2. Enter an identifier or a name for the measurement data.
  • Page 35: Export Data

    AURA handheld NIR Operation Export data There are three different options available for data exchange between the AURA handheld NIR and storage media or PCs running InProcess: • Gigabit Ethernet at 1000 Mbit • internal WIFI • 2 x USB 2.0 The data transfer can be executed via InProcess.
  • Page 36: Exchanging Battery Pack

    Please push the “Power ON button” again after replacement of the battery, to switch the lamp on again. Note The AURA handheld NIR will shut down automatically when the battery exchange takes longer than one minute� 1. Push the “Release buttons” (Fig. 12 / 1) at the battery compartment.
  • Page 37: Fig. 12 Exchanging The Battery Pack

    AURA handheld NIR Operation Standard handle Slanted handle Fig. 12 Exchanging the battery pack Release buttons for the battery compartment Battery compartment Battery pack User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 38: Charging The Battery Pack

    The battery is charged and can be removed for use. • Note To check the charging status of the battery pack, please touch the switch on the battery pack� The LED bar will show the charging status� AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 39: Cleaning And Accessories

    Power cable for charger (with european plug) 000000-0603-965 Carrying case 5000 000000-2321-475 Prediction Engines: Unscrambler X Engine License (CAMO) Version 10.4 000000-2214-740 UCAL (prediction engine, Unity Scientific) 000000-2058-929 ADK Runtime Sensologic 000000-2332-569 Tab. 4 Accessories User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 40: Appendix

    • Data sheet WiFi adapter LM808 (2 pages)  see section 8.5 on page 68 • EU Declaration of Conformity (RED) LM808 (1 page)  see section 8.6 on page 70 AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 41: Technical Data Sheet

    Standard charging station for mobile devices used in medical, industrial and consumer markets DS_RRC-SMB-UBC_I Subject to technical changes without notice * Released document – Copy is not subject to revision service! 1 / 4 User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 42 Voltage dips, short instrumentations & volt- EN/IEC61000-4-11 age variations Immunity characteristics EN55024 DS_RRC-SMB-UBC_I Subject to technical changes without notice * Released document – Copy is not subject to revision service! 2 / 4 AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 43 Australia & New Zealand Russia (Customs Union) Korea China Japan India DS_RRC-SMB-UBC_I Subject to technical changes without notice * Released document – Copy is not subject to revision service! 3 / 4 User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 44 Email: hkrrc@rrc-ps.cn Web: www.rrc-ps.de Web: www.rrc-ps.com Web: www.rrc-ps.com Web: www.rrc-ps.com DS_RRC-SMB-UBC_I Subject to technical changes without notice * Released document – Copy is not subject to revision service! 4 / 4 AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 45: Instruction Manual Battery Pack Rrc 2054

    RRC power solutions GmbH  Technologiepark 1  66424 Homburg/Saar * Germany  www.rrc-ps.com  sales @rrc-ps.de 1 / 31 Manual_RRC2054_D Subject to technical changes without notice * Released document – Copy is not subject to revision service! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 46 Instruction Manual Battery Pack RRC2054 <10% 10-25% 26-50% 51-75% 76-100% 2 / 31 Manual_RRC2054_D Subject to technical changes without notice * Released document – Copy is not subject to revision service! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 47 EAC/Gost China CQC India BIS Thailand TIS Taiwan BSMI 4 / 31 Manual_RRC2054_D Subject to technical changes without notice * Released document – Copy is not subject to revision service! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 48 Zeichen zur Einhaltung der Regularien von Taiwan BSMI Thailand 3 / 31 Manual_RRC2054_D Subject to technical changes without notice * Released document – Copy is not subject to revision service! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 49: Instruction Manual Battery Pack Rrc 2040-02

    RRC power solutions GmbH  Technologiepark 1  66424 Homburg/Saar * Germany  www.rrc-ps.com  sales @rrc-ps.de 1 / 31 Manual_RRC2040-2_C Subject to technical changes without notice * Released document – Copy is not subject to revision service! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 50 Instruction Manual Battery Pack RRC2040-02 <10% 10-25% 26-50% 51-75% 76-100% 2 / 31 Manual_RRC2040-2_C Subject to technical changes without notice * Released document – Copy is not subject to revision service! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 51 EAC/Gost China CQC India BIS Thailand TIS Taiwan BSMI 4 / 31 Manual_RRC2040-2_C Subject to technical changes without notice * Released document – Copy is not subject to revision service! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 52 Zeichen zur Einhaltung der Regularien von Taiwan BSMI Thailand 3 / 31 Manual_RRC2040-2_C Subject to technical changes without notice * Released document – Copy is not subject to revision service! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 53: Safety Data Sheet Rrc Batteries

    01oct2019 components Updated Hazardous components list 07oct2019 Layout Updated SDS_RRC-Batteries_07oct2019_F.pdf Page 1 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 54 Hazardous decomposition products ..................11 10.5. Possibility of Hazardous Reactions ..................11 SDS_RRC-Batteries_07oct2019_F.pdf Page 2 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 55 Full text of R-phrases referred under section 8 ..............15 16.2. Further Information ......................15 SDS_RRC-Batteries_07oct2019_F.pdf Page 3 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 56: Product And Company Identification

    SDS_RRC-Batteries_07oct2019_F.pdf Page 4 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 57: Hazards Identification

    P501: Dispose of batteries in accordance with applicable hazardous waste regulations. SDS_RRC-Batteries_07oct2019_F.pdf Page 5 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 58: Other Hazards

    Because of the cell structure the dangerous ingredients will not be available if used properly. During charge process a lithium graphite intercalation phase is formed. SDS_RRC-Batteries_07oct2019_F.pdf Page 6 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 59: First Aid Measures

    ADVICE TO DOCTOR: Treat symptomatically if the person comes into contact with the corrosive electrolyte liquid contents of a damaged battery. SDS_RRC-Batteries_07oct2019_F.pdf Page 7 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 60: Fire Fighting Measures

    (OCV approx. 3.60 - 3.90 V/cell). Keep in closed original container. SDS_RRC-Batteries_07oct2019_F.pdf Page 8 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 61: Exposure Controls/Personal Protection Exposure Limit Values Exposure Limits

    Full text of each relevant R phrase can be found in chapter 16. SDS_RRC-Batteries_07oct2019_F.pdf Page 9 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 62: Exposure Control Measures

    Density: n.a. Water solubility: Insoluble Ignition temperature: n.a. SDS_RRC-Batteries_07oct2019_F.pdf Page 10 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 63: Stability And Reactivity

    SDS_RRC-Batteries_07oct2019_F.pdf Page 11 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 64: Ecological Information

    13.2. Contaminated packaging Disposal in accordance with local regulations. SDS_RRC-Batteries_07oct2019_F.pdf Page 12 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 65: Transport Information

    Canadian Transport of Dangerous Goods Regulations (TDGR) Special Provision 34 SDS_RRC-Batteries_07oct2019_F.pdf Page 13 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 66: Regulatory Information

    This Safety Data Sheet complies with the requirements of Regulation (EC) No. 1907/2006. SDS_RRC-Batteries_07oct2019_F.pdf Page 14 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 67: Japanese Regulations

    The data for the hazardous ingredients were taken respectively from the last version of the sub-contractor’s safety data sheet. SDS_RRC-Batteries_07oct2019_F.pdf Page 15 of 15 Freigegebenes Dokument [Released document]– Ausdruck unterliegt nicht dem Änderungsdienst [Printout is not subject to change management]! User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 68: Data Sheet Wifi Adapter Lm808

    256QAM modulation of the individual subcarriers and o ers a compatible coding rate of 1/2, 2/3, 3/4, and 5/6, and provides up to 433.3 Mbps over IEEE 802.11ac while using 80MHz bandwidth. LM808 +44(0) 207 428 2647 sales@lm-technologies.com Page 1 of 4 AURA handheld NIR – 2289-971 and 2298-955 | User Manual...
  • Page 69 29.5mm x 15.0mm x 8.0 mm (L x W x H) USB Type A Connector + Housing Weight 3.33g +/- 0.25g tolerance Dimensions 12mm 15mm LM808 +44(0) 207 428 2647 sales@lm-technologies.com Page 2 of 4 User Manual | AURA handheld NIR – 2289-971 and 2298-955...
  • Page 70: Eu Declaration Of Conformity (Red) Lm808

    Mr Michael Sims / Director ..............................Name and signature of authorized person th i Place and date of issue EU Declaration of Conformity (RED) +44(0) 207 428 2647 www.lm-technologies.com sales@lm-technologies.com AURA handheld NIR – 2289-971 and 2298-955 | User Manual...

This manual is also suitable for:

2289-9712298-955

Table of Contents