lancer Bridge Tower Installation Manual

lancer Bridge Tower Installation Manual

Hide thumbs Also See for Bridge Tower:

Advertisement

FOR QUALIFIED INSTALLER ONLY. This basic Installation Sheet is an initial release. If a complete Operations
Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for
immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate
access Contact Lancer Customer Service for assistance as required.
ABOUT THIS MANUAL
This booklet is an integral and essential part of the product and
should be handed over to the operator after the installation and
preserved for any further consultation that may be necessary.
Please read carefully the guidelines and warnings contained
herein as they are intended to provide the user with essential
information for the continued safe use and maintenance of the
product. In addition, it provides GUIDANCE ONLY to the user on
the correct services and site location of the unit.
The installation and relocation, if necessary, of this product must be carried out by qualified personnel with
up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.
IMPORTANT SAFETY INSTRUCTIONS
! Intended Use
The dispenser is for indoor use only. This appliance is to be installed in a location where its use can be overseen by trained
personnel. This unit is not a toy. Children should be supervised not to play with appliance. It should not be used by children or
infirm persons without supervision. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance shall not be performed by
children without supervision. The min/max ambient operating temperature for the dispenser is 4°C to 32°C (40°F to 90°F). Do not
operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of the unit and contact
authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained personnel. Applicable safety
precautions must be observed. Instruction warnings on the product being used must be followed.
®
320
Bridge Tower
BEFORE GETTING STARTED
Each unit is tested under operating conditions and is thoroughly
inspected before shipment. At the time of shipment, the carrier
accepts responsibility for the unit. Upon receiving the unit,
carefully inspect the carton for visible damage. If damage exists,
have the carrier note the damage on the freight bill and file a
claim with carrier. Responsibility for damage to the dispenser lies
with the carrier.
LANCER INSTALLATION GUIDE
LANCER PN: 28-2852/04
Revision: January 2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bridge Tower and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for lancer Bridge Tower

  • Page 1 FOR QUALIFIED INSTALLER ONLY. This basic Installation Sheet is an initial release. If a complete Operations Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate access Contact Lancer Customer Service for assistance as required.
  • Page 2: Specifications

    This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your Lancer Service Agent or Lancer Customer Service.
  • Page 3: Selecting/Preparing Counter Location

    NOTE Cut package banding straps and remove. To assure that beverage service is accessible to all customers, Lancer recommends that counter height Open the box and remove the accessory kit and loose parts. and equipment selection be planned carefully. The...
  • Page 4: Dispenser Setup

    NOTE NOTE NSF listed units must be sealed to the counter. Unit is designed to be supported by a remote chiller system or remote ice cooled system. Please see the manufacturer’s specifications and instructions for Place gasket at the bottom of the drain then re-attach drain installation.
  • Page 5 Twist the key-lock rod, located behind the splash plate, to Slide the front panel off of the dispenser by leaning the top of unlock the head of the tower. the panel forward then slide off of the dispenser. A. Key-Lock Rod A.
  • Page 6 - Tap Four Corners of Screen 19. A keypad will appear, enter the designated pin number to access the service menu. NOTE Contact Lancer Customer Service for the units’ designated pin number. A. Purge Tab B. Up to 4 Purge Buttons Selected...
  • Page 7: Adding New Brand/Flavor Module

    From here, choose the desired function and valve type for NOTE the incorporated valve module. Once the purge is activated, it will continue to dispense product until it is deactivated. To deactivate the purge, simply press the Purge button again. Up to four modules can be purged at one time.
  • Page 8: Calibration And Maintenance

    Select a new brand from the available Brands Library tabs NOTE on the left side of the screen. Each brand has a default water type and ratio already set when they are selected. The water type and ratio can be adjusted if necessary, adjust the ratio by selecting the “Ice”...
  • Page 9: Calibrating Brand Syrup Modules

    Graduated Cylinder: With the graduated cylinder placed in a position below the nozzle, press the Start Purge button. The unit will dispense From the Service menu, press the Maintenance button. the volume designated in the previous step. Press the calibrate tab on the far left side of the screen and press the Calibrate button for the first brand syrup module.
  • Page 10 (See page 7, Adding New Brand/Flavor Module) A. Syrup Separator in Place of Nozzle Using a Lancer ratio cup, activate the brand syrup module by pressing and holding the Dispense button. Release the button to deactivate the module and capture a sample.
  • Page 11: Scheduled Maintenance

    Increase Decrease A. Flow Control B. Valve Retainer C. Solenoid D. Valve Body Repeat steps 7 and 8 if any more brand syrup flow adjustment is necessary. 10. Repeat steps 2-9 for the remaining brand syrup modules. 11. Press the Maintenance button to return to the Maintenance screen and then press the Menu button to return to the Service menu.
  • Page 12: System Settings

    B. Sold Out Sensors 1-10 C. CO Low Pressure Indicator NOTE For more information on other Bridge Tower features such as Lighting, Portion Control, and Water Buttons, refer to the unit Operations Manual (Lancer PN: 28-0941/02) located on the Lancer Corp website (lancercorp.com) or for more immediate access, scan...
  • Page 13: Data Management

    Plug the USB into the Bridge Tower port located underneath the head of the tower. Once both the video file and list.txt file are in the “ss” folder on the USB Drive, plug in the drive into the Bridge Tower port located underneath the head of the tower. NOTE Multiple videos can be uploaded at one time, just add the name of each video to the “list.txt” file, one...
  • Page 14: Cleaning And Sanitizing

    General Information ! CAUTION • Lancer equipment (new or reconditioned) is shipped from If a powder sanitizer is used, dissolve it thoroughly the factory cleaned and sanitized in accordance with NSF with hot water prior to adding to the syrup system.
  • Page 15: Wiring Diagram

    Wash nozzle with cleaning solution then immerse in Connect power. sanitizing solution and let sit for fifteen (15) minutes. 10. Taste the drink to verify that there is no off-taste. If off-taste Set nozzle aside and let air dry. DO NOT rinse with water is found, sanitize the nozzle and nozzle injectors again.
  • Page 16: Plumbing Diagram

    This software is distributed WITHOUT ANY WARRANTY. While you are free to modify and install software licensed under the GNU General Public License (GPL) or GNU Lesser General Public License (LGPL), Lancer does not provide technical support or warranty service for equipment running modified software.

Table of Contents