Troubleshooting - L.A. Spas In-Fit 13 SL Manual

Table of Contents

Advertisement

TROUBLESHOOTING

HEATING SYSTEM
Symptom
Spa water cold / spa not
heating
Spa water too warm /
spa heating above set
point
Spa temperature erratic
36
Problem
1. Temperature setting is
not at user select.
Power reset
caused default setting
2. Spa in economy mode
3. Dirty filters
4. Air lock
5. Jets closed obstructing
flow
6. Pump gate valve closed
7. Equipment malfunction
1. Temperature setting too
high
2. Too much filtration
3. Thermal Creep
4. Dirty filters
5. Overheat or high limit
occurred
6. Equipment malfunction
1. Water level low
2. Spa in economy mode
3. Dirty filters
4. Jets closed obstructing
flow
5. Pump gate valve closed
6. Equipment malfunction
Corrective Action
1. Increase temperature
2. Reset to standard mode.
3. Clean filters
4. Prime pump (see page 10)
5. Open jets
6. Open gate valve
7. Call for service
1. Decrease temperature
2. Reduce the number of filter
cycles and/or the filter
cycle duration
3. Refer to Thermal Creep
Section (p. 13)
4. Clean filters
5. Call for service
6. Call for service
1. Fill with water to 5" (13cm)
below the top of spa
2. Reset to standard mode
3. Clean filters
4. Open jets
5. Open gate valve
6. Call for service
In-Fit Exercise Pools

Hide quick links:

Advertisement

Table of Contents
loading