WATER SYSTEM
Symptom
Pulsating jets
No jet action or action
is poor
ELECTRICAL SYSTEM
Symptom
Spa will not turn on in
any mode
Spa turns on by itself
Light is out
Pump shuts down unex-
pectedly while in use
In-Fit Exercise Pools
Problem
1. Water level low
2. Dirty filters
3. Filter intake / pump
intake restricted
4. Pump gate valve closed
5. Equipment malfunction
1. Jets are turned off
2. Diverter valve turned
3. Water level low
4. Dirty filters
5. Pump gate valve closed
6. Air lock
Problem
1. No power
2. Equipment malfunction
1. Normal automatic daily
filtration cycle
2. Spa required heat to
maintain temperature
3. Freeze protection
engaged
4. Equipment malfunction
1. Automatic time out has
shut off light.
2. Burned out light bulb
1. Automatic timeout has
shut pump off
2. Motor overheated and
protective device has
shut down pump
Corrective Action
1. Fill with water to 5" (13cm)
below the top of spa
2. Clean filters
3. Remove obstruction
4. Open gate valve
5. Call for service
1. Turn jets on by turning jet
face
2. Turn the diverter valve
clockwise or counterclock-
wise
3. Fill with water to 5" (13cm)
below the top of spa
4. Clean filters
5. Open gate valve
6. Prime pump (see page 26)
Corrective Action
1. Check circuit breaker and/
or GFCI
2. Call for service
1. No action required
2. No action required
3. No action required
4. Call for service
1. Press Light key again to
start another cycle.
2. Replace light bulb
1. Press Jets keys again to
start another cycle
2. Allow pump to cool. If
the pump does not
restart when Jets key is
pressed, call for service