HEATING SYSTEM
Symptom
Spa water cold / spa not
heating
Spa water too warm / spa
heating above set point
Spa temperature erratic
WATER SYSTEM
Symptom
Pulsating jets
No jet action or action is
poor

TROUBLESHOOTING

Problem
1. Temperature setting is not at
user select. Power reset caused
default setting.
2. Spa in economy mode
3. Dirty filters
4. Air lock
5. Jets closed obstructing flow
6. Equipment malfunction
1. Temperature setting too high
2. Too much filtration
3. Dirty filters
4. Overheat or high limit occurred
5. Equipment malfunction
1. Water level low
2. Spa in economy mode
3. Dirty filters
4. Jets closed obstructing flow
5. Pump gate valve closed
6. Equipment malfunction
Problem
1. Water level low
2. Dirty filters
3. Filter intake / pump intake
restricted
4. Pump gate valve closed
5. Equipment malfunction
1. Jets are turned off
2. Water level low
3. Dirty filters
4. Air lock
1. Increase temperature
2. Reset to standard mode.
3. Clean filters
4. Prime pump (see page 12)
5. Open jets
7. Call for service
1. Decrease temperature
2. Reduce the number of filter
3. Clean filters
4. Call for service
5. Call for service
1. Fill with water to 4" (10 cm)
2. Reset to standard mode
3. Clean filters
4. Open jets
5. Open gate valve
6. Call for service
1. Fill with water to 4" (10 cm)
2. Clean filters
3. Remove obstruction
4. Open gate valve
5. Call for service
1. Turn jets on by turning jet face
3. Fill with water to 4" (10 cm)
4. Clean filters
6. Prime pump (see page 12)
21
Corrective Action
cycles and/or the filter cycle
duration
above top of the filters
Corrective Action
above top of the filters
counterclockwise
above top of the filters

Hide quick links: