Electrical Connections - L.A. Spas In-Fit 13 SL Manual

Table of Contents

Advertisement

IMPORTANT INFORMATION REGARDING ELECTRICAL INSTALLATION
NORTH AMERICA
Equipment Type
2 pumps
4 pumps
5 pumps
EXPORT
Equipment Type
2 pumps
4 pumps
2 pumps
4 pumps
1.
Circuit breaker amperages may vary according to the area of installation. Please check local
electrical codes to verify requirements and assure compliance. Spas purchased not fully
equipped may operate at a reduced total amp rating thus allowing installation of a lower rate
GFCI/RCD circuit breaker and service installation.

ELECTRICAL CONNECTIONS

To hook up your spa your authorized dealer or licensed electrician should follow
these instructions:
1.
Remove the front cabinet panel.
2.
Remove the cover for the equipment control pack.
3.
Use ¾" flexible non-metallic conduit for a spa requiring 10 AWG or 8 AWG wire. Use 1"
flexible non-metallic conduit for a spa requiring 6 AWG wire. Run the conduit from the
power source to the spa, through the hole in the left or right front corner of the spa and
into the equipment control pack.
4.
Pull the wires/cable through the conduit and through the cutout of the equipment
control pack. Secure the wires/cable with a 1" strain relief. Make sure only the uncut
sheathing is clamped at this opening.
5.
Connect the wires to the proper terminals as shown below:
16
Electrical Rating
240V 40A
240V 48A
240V 48A
Electrical Rating
230V 32A
230V 32A
230V 32A
230V 32A
Branch Circuit
3 wires + ground
3 wires + ground
3 wires + ground
Branch Circuit
2 wires + ground
2 wires + ground
2 wires + ground
2 wires + ground
Circuit Break
1
50A
60A
60A
Circuit Breaker
1
32/40A
32/40A
32/40A
32/40A
In-Fit Exercise Pools

Hide quick links:

Advertisement

Table of Contents
loading