Operation; Standard Operation; Cleaning - CAB 4114 Service Manual

Stroke applicator
Hide thumbs Also See for 4114:
Table of Contents

Advertisement

3

Operation

10
3.1

Standard Operation

 Check all external connections.
 Load the material.
 Open the shutoff valve.
!
Attention!
 Ensure that the pad is not covered by a label when switching on the printer-applicator system.
Otherwise the vacuum sensor may be calibrated faultily.
 Switch on the printer.
i
Note!
If the pad is not in the start position when the printer is switched on an error message appears on the
display.
Press pause button at the printer.
The applicator moves into the start position and is ready for work.
 Press the feed button on the printer.
A synchronization feed is initiated. The processed labels have to be removed manually. After a few seconds the
printer carries out a short backfeed to position the front edge of the next label at the printing line.
i
Note!
This synchronizing also has to be carried out when the print job has been interrupted with the cancel button.
Synchronizing is not necessary when the print head was not lifted between print jobs. This also applies if
the printer was powered off between print jobs.
 Start a print job.
 Start the labelling process via PLC interface.
Error messages during labelling process are shown in the display of the printer. „4 Error Messages"
3.2

Cleaning

!
Attention!
Never use solvent and/or abrasive.
Fig. 6
Cleaning the pad
 Clean the outside surfaces with multi purpose cleaner.
 Remove dust particles and leftover label pieces with a soft
brush and/or vacuum cleaner.
 The slide foil (1) requires regular cleaning as most of the
dirt will accumulate here.
1
1
10