Mechanical Installation; Pneumatic Installation - Festo VPPI D Series Assembly, Installation And Operating Instructions

Proportional-pressure regulator
Hide thumbs Also See for VPPI D Series:
Table of Contents

Advertisement

Installation
Fig. 10 Linked valves
7.3

Mechanical Installation

1. Make sure there is sufficient space for the connecting cable and tubing connections.
Ä This will prevent kinks from forming in the connecting cables and the tubing.
2. Place the valve as close to the consumer as possible.
Ä This leads to improved control precision and shorter response times.
8
Installation
8.1

Pneumatic Installation

Valves for Standard Operation (Overpressure)
1. Attach the tubing to the connections:
Compressed air (1)
Working air (2)
2. Fit a silencer at the exhaust air connection (3) or provide for ducted exhaust air.
Valves for Vacuum Operation and Combined Vacuum / Overpressure Operation (VPPI -...- 1V... H -...)
1. Attach the tubing to the connections:
Vacuum (3)
Working air (2)
2. Connect a compressed air supply to port (1) or mount a silencer to protect the valve from coarse
dirt particles.
10
Festo — VPPI-...-D — 2019-12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents