Safety equipment

6.3 Dismantling the stop switch

1
Carefully remove the stop switch using a flat
screwdriver or similar tool. See figure 3 or figure 4
for R-handle.
2
Disconnect the cables.
Cleaning and inspection
Clean and check the power switch carefully.
Replace parts that are broken or show signs of
other defects. Always use original spare parts.

6.4 Assembling the stop switch

1
Connect the cables. See figure 3 or figure 4 for
R-handle.
2
Fit the stop switch.
6.5 Resistance test - stop switch
1
Dismantle the stop switch as outlined in
"6.3 Dismantling the stop switch".
2
Clean the contact areas.
3
Test the resistance by connecting a multimeter to
the stop switch. See figure 4. The resistance should
be as follows:
1 = 0.1 Ω
STOP = 1000 Ω