Connecting Throttle Cable And Stop Switch Wires - Husqvarna 541RS Operator's Manual

Hide thumbs Also See for 541RS:
Table of Contents

Advertisement

Available languages

Available languages

H1159210-30, GBESPT Page 13 Friday, October 6, 2017 1:00 PM
Tighten the screws.
Connecting throttle cable and
stop switch wires
1
Remove the air filter cover.
2
Insert the throttle cable (A) through the carburettor
bracket (B), then screw the cable adjuster sleeve (C)
into the carburettor bracket fully.
3
Position the slotted fitting (D) on the carburettor so the
recessed hole (E) for the cable lug (F) is away from the
cable adjuster sleeve.
4
Rotate the carburettor throttle cam and slip the throttle
cable through the slot in the slotted fitting, making
sure the cable lug drops into the recessed hole.
5
Operate the throttle trigger a few times to make sure
that it works correctly.
6
Adjust the cable adjuster sleeve so the stop on the
carburettor throttle cam just contacts the throttle stop
and the cable position keep 1-2 mm play between the
ASSEMBLY
cable lug and the slotted fitting when the throttle
trigger is fully depressed.
1-2mm
7
When the throttle cable is adjusted correctly, tighten
the locking nut (G).
8
Plug the stop switch wires (H) into the matching
connectors from the engine. Note that wire polarity is
not important.
H
9
Insert the short circuit cable into the groove on the
filter holder.
10 Fit the dust cover (J).
11 Refit the air filter cover.
J
English
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

531rs541rst236r

Table of Contents