March 2020
3

Initial connection and configuration

To configure the Gateway, a local connection between a computer and the
Gateway needs to be established.
Powering the Gateway
For the Emerson 1410S, bench top power will be needed to power the
Gateway by wiring a 10.5–30 VDC (24 VDC if configured with I.S. barriers)
power source.
Figure 3-1: Emerson 1410S Gateway Wiring
A. Mounting plate
B. Antenna terminal 1 power and data connections
C. Antenna terminal 2 power and data connections
D. Ethernet port 1. When this port is activated, the factory IP address is
192.168.1.10.
E. Ethernet port 2. When this port is activated, the factory IP address is
192.168.2.10.
F. Emerson 1410S power and serial connections
G. Power output
H. RS-485 comm
I. 10.5 to 30 VDC power input
J. Serial modbus
WARNING
Conduit/cable entries
The conduit/cable entries in the transmitter housing use a ½–14 NPT thread
form.When installing in a hazardous location, use only appropriately listed or
Ex certified plugs, glands, or adapters in cable/conduit entries.