Mitsubishi Electric MELSEC iQ-F Series Quick Start Manual page 46

Safety extension module
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

APPENDICES
Safety Application
Example
7
Entire logics
The following show the entire logics using inputs 1) to 10) and outputs Q0 to Q3.
1)
8
Q0
Q2
9
Q1
MU
Operations
[Entire stop]
When any one of the inputs 1) and 3) to 6) turns OFF, all the outputs Q0 to Q3 turn OFF.
[Partial stop]
When any one of the inputs 2) and 7) to 10) turns OFF, only the outputs Q2 and Q3 turn OFF.
46
Increasing Safety
Safety Extension Module
Inputs
Configuration Guide
2)
3)
4)
5)
6)
7)
8)
9)
10)
Q3
2nd 8DI
1st 8DI
Buffer Memory
1)
3)
&
4)
5)
&
6)
2)
7)
&
8)
9)
&
10)
*1: This is an off delay time. The factory default setting of the rotary switch is 0 second.
Sequence Program
Partner Products
Example
Safety output
Q0
&
Safety output
Q1
Safety output
Q2
&
&
*1
Safety output
Q3