To interpret the status LED, see the following table.
Restriction
If LED Blinking is disabled, the status LED will flash only during calibration. It will not flash to indicate
an unacknowledged alarm.
Table 8-1:
LED behavior
Solid green
Solid yellow
Flashing yel-
low
Solid red
Flashing red
8.5

View and acknowledge status alerts

The transmitter posts status alerts whenever a process variable exceeds its defined limits
or the transmitter detects a fault condition. You can view active alerts, and you can
acknowledge alerts. Acknowledging alerts is not required.
8.5.1

View and acknowledge alerts using ProLink III

You can view a list containing all alerts that are active, or inactive but unacknowledged.
From this list, you can acknowledge individual alerts or choose to acknowledge all alerts at
once.
1.
Configuration and Use Manual
Status LED states
Alarm condition
No alarm
Active low-severity alarm
Active low-severity alarm
Active high-severity alarm
Active high-severity alarm
View and acknowledge alerts using ProLink III
View alerts on the ProLink III main screen under Alerts.
All active or unacknowledged alerts are listed, and displayed according to the
following categories:
Category
Description
Failed: Fix Now
A meter failure has occurred and must be addressed immediately.
Maintenance: Fix Soon
A condition has occurred that can be fixed at a later time.
Advisory: Informational
A condition has occurred, but requires no maintenance from you.
Description
Normal operation
Alarm has been acknowledged
Alarm has not been acknowledged
Alarm has been acknowledged
Alarm has not been acknowledged
(Section 8.5.1)
Transmitter operation
57