Dmx Output (Optional) - Harvia sentiotec home.com4 Instructions For Installation And Use Manual

Sauna control unit
Hide thumbs Also See for sentiotec home.com4:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 66
Installation instructions, only for experts

5.13. DMX output (optional)

1. Guide the DMX connection cables for the heater sensor through the cable
gland 7 into the low-voltage connection area.
2. Connect the DMS connection cables in accordance with the designations
on terminal strip f.
- DMX A (DATA +)
- DMX B (DATA -)
- GND (ground/shield)
Four different DMX protocols are supported, which are output at the same time
on the DMX output:
1. 8-bit RGBW
2. 16-bit RGBW
3. 8-bit hue value saturation (such as for COLLAXX coloured light devices)
4. 8-bit hue saturation value
Use the following address overview to integrate your coloured light unit into
the sauna control unit.
RGBW_8BIT
● Start address: Channel 1
► Channel light group 1:
► Channel light group 2:
► Channel light group 3:
► Channel light group 4:
RGBW_16BIT
● Start address: Channel 17
► Channel light group 1:
► Channel light group 2:
► Channel light group 3:
► Channel light group 4:
1
5
9
13
17
25
33
41
p. 25/64