Installation instructions, only for experts

5.4. Connecting the fan (optional)

1. Guide the fan cable through the cable bushing
for 230 V/400 V
2. Connect the fan cable to the terminal strip
tion diagram. Observe the operating instructions for the respective device.

5.5. Connecting the additional output (optional)

The additional output can, for example, be used for an infrared lamp or infrared
heat plates.
WARNING!
Risk of fi re
The additional output does not feature an excess temperature fuse. For
this reason, only intrinsically safe devices should be operated using the
additional output.
● If infrared lamps are connected to the additional output, these must
have an excess temperature fuse.
● If infrared heat plates are connected to an additional output, the foil
sensor P-ISX-FF must be used, and must be activated when fi rst start-
ing operation (see 8.5. Activating/deactivating the foil sensor on
page 26).
1. Guide the connection cable for the additional device through the cable bush-
ing
into the connection area for 230 V/400 V
8
2. Connect the power supply cables to the terminal strip
the connection diagram. Observe the operating instructions and safety in-
structions for the respective device.

5.6. Connecting the power booster (optional)

1. Guide the cable for the power booster through the cable bushing
connection area for 230 V/400 V
2. Connect the cable for the power booster to the terminal strip
cordance with the connection diagram. To do so, use terminal
"ST1" for the safety circuit, and terminal "ST2" for the control circuit.
Observe the operating instructions for the respective device.
WORLD OF WELLNESS
.
g
g
into the connection area
c
in accordance with the connec-
e
.
g
d
.
p. 19/40
in accordance with
into the
b
in ac-
f
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sentiotec just-105d-fiSentiotec just-105w-fi

Table of Contents