Cw-3000 Water Chiller - Filament Innovations BFP-ICARUS-TYPHOON Manual

Table of Contents

Advertisement

CW-3000 Water Chiller

The Gen-4 ICARUS is water-cooled and we include the CW-3000 water
chiller to keep the Typhoon high-flow extruder operating at the
appropriate temperatures, between 18C and 28C.
IMPORTANT – FROM THIS STEP FORWARD - IF THE MACHINE IS ON, THEN THE
CHILLER NEEDS TO BE ON. ALWAYS LEAVE THE CHILLER SWITCH TO THE "ON"
POSITION AS THE POWER IS DERIVED FROM THE PRINTER ITSELF. THE CHILLER
WILL TURN OFF WHEN THE POWER TO THE PRINTER IS TURNED OFF. THE
CHILLER WILL BEEP MULTIPLE TIMES WHEN TURNED ON.
Please note – you will need to source 2 gallons of blue windshield washer
fluid. This is commonly sold at any general store or automotive store.
1. Place the water chiller next to the machine and connect the two water
lines coming out on the back. It does not matter which line goes into
the Input line or the Output line. Secure these lines to the chiller using
the included clamps.
2. Fill the reservoir (located on the top of the chiller), with roughly 1.75
gallons of windshield washer fluid.
3. Plug the power cord into the chiller. The power for the chiller is taken
from the power cord hanging from the back of the printer.
4. With the two hoses connected, the reservoir filled, and the power cord
plugged in, flip the power switch on the chiller. If the printer is powered
on, the water chiller will beep a few times and fluid will flow. Check the
Typhoon connections for any leaks. If the chiller does not turn on, check
that the power cord is plugged, the chiller is turned on, and the printer is
on.