6

Servicing explosion-protected devices

If a part of the positioner on which the ex-
plosion protection is based needs to be ser-
viced, the positioner must not be put back
into operation until an expert has inspected
the device according to explosion protection
requirements, has issued a certificate stating
this or given the device a mark of confor-
mity.
Inspection by an expert is not required if the
manufacturer performs a routine check on
the device prior to putting it back into oper-
ation. The passing of the routine check must
be documented by attaching a mark of con-
formity to the device.
7

Accessories and mounting parts

Accessories – Mounting parts
Range spring 1
Range spring 2
Range spring 3
Lever I
Lever extension
Pressure gauge attachment
Pressure gauge attachment, free of copper
Mounting kit for valves with cast yoke acc. to NAMUR
Mounting kit for valves with rod-type yokes acc. to NAMUR
for rod diameters 18 to 35 mm
Spare parts assortment with seals and diaphragms
Conversion kit to upgrade to degree of protection IP 65
(refer to SAMSOMATIC print Z 900-7 for more details)
Servicing explosion-protected devices
Explosion-protected components may only
be replaced by original, checked compo-
nents from the manufacturer.
Devices that have already been used outside
of hazardous areas and are intended for
use in hazardous areas in future must com-
ply with the safety demands placed on re-
paired devices. Prior to operation, they must
be tested according to the specifications
stipulated for "Repairing explosion-pro-
tected devices".
Order number
1190-0736
1190-0737
1190-0738
1690-6469
1400-6716
1400-6950
1400-6951
1400-5745
1400-5745
and 1400-5342
1400-6792
1790-7408