1.4

Specifications

Parameter
Environmental
Ambient Temperature
Rated
Operative (display)
Transportation/Storage
Humidity (% RH)
Reference
Rated
Operative
Transportation/Storage
Design Specifications
Electrical Compatibility
Functional Compatibility
Reverse Polarity Protection
Cable Length
Display
Display Resolution
Display Update Rate
Display Performance
Notes
1. The Remote Indicator must be connected to the local HART compatible bus of the Enraf
Smartradar FlexLine or the Enraf SmartServo 954.
2. Refer to HART Communication Foundation document number HCF_SPEC-54 (FSK
Physical Layer Specification) for detailed length calculations.
Revision 1

Table 2: Specifications

Deg. C
-40 to 85 °C
-20 to 70 °C
-50 to +100°C
To be used with Honeywell Enraf FlexLine Gauges only.
See note 1.
To be used with Honeywell Enraf FlexLine Gauges only.
See note 1.
Yes
1000 Meter. See note 2.
Advanced graphical display
1 second
The LCD display may turn blank below -20 °C and above
70 °C (-4°F and 158°F). The display will again be readable
when temperatures return to within operable limits.
RMA805 Enraf FlexLine Remote Indicator User's manual
Deg. F
-40 to +185°F
-4 to +158°F
-58 to +212°F
10 – 55% RH
5 – 100% RH
5 – 100% RH
5 – 100% RH
3