Command
Group master level (volume and mute)
NOTES:
•
The DTP CrossPoint 84 has 16 configurable group masters.
•
By factory default, group 1 controls the program volume and group 2 controls the mic volume.
•
Other group masters (such as mutes) must be preset (have already been created) in the DSP Configurator program to be available as
for SIS commands.
Set gain (+) or attenuation (−) dB
value
Example:
Increment dB value
Example:
Decrement dB value
View master value
Set mute or unmute
KEY:
X#
= Mute
0 = off (unmuted)
X1)
= Group number
01 – 16 (can be a user-defined alias enclosed in brackets {})
X1!
dB value in 0.1 increments. Example: X1! = 50 = 5 dB.
= Group master value
SIS Command
Response
(Host to Unit)
(Unit to Host)
E
X1)
X1!
}
X1)
D
*±
GRPM
GrpmD
E
}
D1*+50GRPM
GrpmD1*50
E
X1)
X1!
}
X1)
D
*
+GRPM
GrpmD
E
}
D1*75+GRPM
GrpmD1*125
E
X1)
X1!
}
X1)
D
*
−GRPM
GrpmD
E
X1)
}
X1!]
D
GRPM
E
X1)
X#
}
X1)
D
*
GRPM
GrpmD
1 = on (muted)
Additional Description
X1!]
*
Specify + for gain or - for attenuation.
]
Specify 5 dB level for group 1 (program volume).
X1!]
*
Increase master
]
Increase group 1 (program volume) by 7 . 5 dB (to 12 . 5
dB).
X1!]
*
Decrease master
X#]
Mute ( 1 ) or unmute ( 0 ) the group.
*
X1)
X1)
X1!
by
.
X1)
X1!
by
.
s