Graco Renegade Series Operation - Repair - Parts page 35

Torque series pump
Table of Contents

Advertisement

6.
Use a 5 mm Allen wrench to remove the
three M6 screws that secure the diverter
block to the manifold. Remove the
diverter block.
7.
Make certain the old o-rings are
removed from the manifold.
NOTICE
Failure to remove existing o-rings from
manifold could result in equipment damage
if multiple o-rings are re-installed into the
valve manifold upon reassembly.
3A6884B
Install 4-Way Valve
1.
Remove finger-tight nut on top of new
valve. Remove coil from new valve.
2.
Using a 5 mm Allen wrench, carefully
separate the 4-way valve from the
diverter block. Ensure o-rings remain in
place on 4-way valve. Set valve aside on
a clean surface.
3.
To remove the protective cover from the
bottom of the diverter block remove the
three hex nuts. Dispose of the three hex
nuts and protective cover.
Repair
35

Advertisement

Table of Contents
loading

Table of Contents