Graco Renegade Series Operation - Repair - Parts page 27

Torque series pump
Table of Contents

Advertisement

Problem
TSP power pack does not run at all.
Display shows CODE 16.
TSP power pack does not run at all.
Display shows CODE 17.
3A6884B
Cause
Motor position sensor not
working.
TSP power pack plugged
into wrong voltage.
Troubleshooting
Solution
1.
Set TSP power pack to OFF and
disconnect power to TSP power
pack.
2.
Open control box by removing 8
screws that attach control assembly
to control box.
3.
Disconnect motor position sensors
and inspect for damage at
connectors.
4.
Reconnect sensor.
5.
Turn power ON. If code continues,
replace motor.
1.
Set TSP power pack to OFF and
disconnect power to TSP power
pack.
2.
Locate a good voltage supply to avoid
damage to electronics.