Graco Renegade Series Operation - Repair - Parts page 25

Torque series pump
Table of Contents

Advertisement

Problem
TSP power pack does not run at all.
Display shows CODE 06.
3A6884B
Cause
Motor overheated.
Troubleshooting
Solution
Note: Motor must be cooled down for the
test.
1.
Keep TSP power pack in cooler
location with good ventilation. Make
sure motor air intake is not blocked.
2.
Set TSP power pack to OFF and
disconnect power to TSP power
pack.
3.
Open control box by removing 8
screws that attach control assembly
to control box.
4.
Check thermal switch inside control
box.
5.
Disconnect 6-pin connector. Make
sure contacts are clean and secure.
Measure resistance of the thermal
switch (thermal switch is across pins
5 & 6). If reading is not correct,
replace motor.
6.
Check Motor Thermal Switch:
Unplug thermal wires. Set meter to
ohms. Meter should reach the proper
resistance across pins 5 & 6.
Resistance Table:
TSP Power Pack
7.
Reconnect 6-pin connector. Connect
power, turn TSP power pack ON and
press Advance Switch. If TSP power
pack does not run, replace control
board.
0 ohms
25

Advertisement

Table of Contents
loading

Table of Contents