7.
Press the TSP power pack Advance
Switch. Set pressure to 8000 psi per the
calibration gauge or data acquisition
system. While keeping the power pack
running at 8000 psi, press the Display
Button to lock in the 8000 psi value for
the controller.
NOTE: If calibration procedure is successful,
DONE will display on the screen for three
seconds, and then pack will return to normal
operation mode.
3A6884B
NOTE: If the calibration procedure was
unsuccessful, the following message will
scroll on the Display: CALIBRATION
FAILED. Press Display Button to continue.
Perform Pressure Relief Procedure page
10, then cycle power to the TSP power pack
and retry calibration procedure.
NOTE: If calibration procedure is never
successful, replace pressure transducer; see
Transducer Replacement page 37.