Working with measurement tools
16.8.4.1 Setting up an alarm for a spot
Follow this procedure:
1. To select the spot, touch the tool on the screen. The tool is now displayed with a
frame.
2. Push the joystick—or touch and hold the tool. This displays a context menu.
3. Use the joystick to go to
4. Push the joystick. This displays a dialog box where you can define the settings for the
alarm.
• Alarm condition: The condition that triggers the alarm. Applicable values are
Above, Below, or Off.
• Alarm limit: The temperature value that will be the critical condition when an alarm
is triggered or not.
• Alarm sound: Applicable values are Beep or No sound.
5. Push the joystick. This closes the dialog box.
6. Push the joystick and select
16.8.4.2 Setting up an alarm for a box, circle, or line
Note This procedure assumes that you have previously set the camera to display at
least one value (maximum, minimum, or average) in the result table.
Follow this procedure:
1. To select the measurement tool, touch the tool on the screen. The tool is now dis-
played with one or more handles.
2. Push the joystick—or touch and hold the tool. This displays a context menu.
3. Use the joystick to go to (depending on tool)
or (Graph/Max/Min/Avg/Alarm).
4. Push the joystick. This displays a submenu.
5. Select
(Set alarm).
6. Push the joystick. This displays a dialog box where you can define the settings for the
alarm.
• Alarm condition: The condition that triggers the alarm. Applicable values are
Above, Below, or Off.
• Select measurement: Applicable settings are the values you have previously de-
fined (Max, Min, and/or Avg).
• Alarm limit: The temperature value that will be the critical condition when an alarm
is triggered or not.
• Alarm sound: Applicable values are Beep or No sound.
7. Push the joystick. This closes the dialog box.
8. Push the joystick and select
16.8.4.3 Setting up an alarm for a difference calculation
Note
• You can set up an alarm for a difference calculation when defining user presets, or
when editing an image in the archive.
• This procedure assumes that you have previously set up a difference calculation.
Follow this procedure:
1. Select
(Add measurement). This displays a submenu.
2. Select
(Select). This displays a dialog box.
3. Select Delta. This displays a context menu.
GlobalTestSupply
4. Use the joystick to go to
www.
#T559880; r. AM/56659/56659; en-US
(Set alarm on spot).
(Done).
,
, or
(Done).
(Set alarm on delta).
.com
sales@GlobalTestSupply.com
(Max/Min/Avg/Alarm)
48

Advertisement

Table of Contents
loading

Table of Contents