Shutdown Alarms - Woodward easYgen-1700 Operation Manual

Genset control
Hide thumbs Also See for easYgen-1700:
Table of Contents

Advertisement

Appendix
Alarms and Warnings > Shutdown Alarms
No
Type
14
Gen. reverse power
15
Overload
16
ECU warning alarm
17
Gen. loss of phase
18
Gen. phase rotation mismatch
19
Breaker open/close fail
20
Temperature sensor wire break
21
High temperature
22
Low temperature
23
Oil pressure sensor wire break
24
Low oil pressure
25
Fuel level sensor wire break
26
Low fuel level
27
Analog input 4 Wire break
28
Analog input 4 High limit
29
Analog input 4 Low limit
30
Analog input 5 Wire break
31
Analog input 5 High limit
32
Analog input 5 Low limit
33
Discrete input xyz
34
GSM Communication fail
35
Ground fault
4.1.3

Shutdown Alarms

28
Description
If reverse power detection is enabled, when the controller detects that the reverse
power value (power is negative) has fallen below the pre-set value and the selected
action is "Warn", it will initiate a warning alarm.
If over power detection is enabled, when the controller detects that the over power value
(power is positive) has exceeded the pre-set value and the selected action is "Warn", it
will initiate a warning alarm.
If an error message is received from ECU via J1939, it will initiate a warning alarm.
If loss of phase detection is enabled, When controller detects the generator loss phase,
it will initiate a warning alarm.
When the controller detects a phase rotation error, it will initiate a warning alarm.
When the controller detects that the breaker close or open failure occurs, and the
selected action is "Warn", it will initiate a warning alarm.
When the controller detects that the temperature sensor is open circuit and the selected
action is "Warn", it will initiate a warning alarm.
When the controller detects that engine temperature has exceeded the pre-set value, it
will initiate a warning alarm.
When the controller detects that engine temperature has fallen below the pre-set value,
it will initiate a warning alarm.
When the controller detects that the oil pressure sensor is open circuit and the selected
action is "Warn", it will initiate a warning alarm.
When the controller detects that the oil pressure has fallen below the pre-set value, it
will initiate a warning alarm.
When the controller detects that the level sensor is open circuit and the selected action
is "Warn", it will initiate a warning alarm.
When the controller detects that the fuel level has fallen below the pre-set value, it will
initiate a warning alarm.
When the controller detects that the flexible sensor 1 is open circuit and the selected
action is "Warn", it will initiate a warning alarm.
When the controller detects that the sensor 1 value has exceeded the pre-set value, it
will initiate a warning alarm.
When the controller detects that the sensor 1 value has fallen below the pre-set value, it
will initiate a warning alarm.
When the controller detects that the flexible sensor 2 is open circuit and the selected
action is "Warn", it will initiate a warning alarm.
When the controller detects that the sensor 2 value has exceeded the pre-set value, it
will initiate a warning alarm.
When the controller detects that the sensor 2 value has fallen below the pre-set value, it
will initiate a warning alarm.
When digit input port is set as warning and the alarm is active, it will initiate a warning
alarm.
When select GSM enable but the controller couldn't detect GSM model, controller sends
corresponding warning signal.
If earth fault detection is enabled, the controller will initiate a shutdown alarm it it detects
that the earth fault current has exceeded the pre-set value and the selected action is
"Warn", it will initiate a warning alarm.
When controller detects shutdown alarm, it will send signal to open
breaker and shuts down generator.