Selected File Is Incompatible; Slow Or Missing Clock - HP E2466C User Manual

Preprocessor interface for the intel pentium ii processor
Table of Contents

Advertisement

If You Have a Problem

"Selected File is Incompatible"

"Selected File is Incompatible"
This occurs when you try to load a configuration file for the wrong module.
Ensure that you are loading the appropriate configuration file for your logic
analyzer.

"Slow or Missing Clock"

This error message might occur if the logic analyzer cards are not firmly
seated in the HP 16500B/C or HP 16501A frame. Ensure that the cards
are firmly seated.
This error might occur if the target system is not running properly.
Ensure that the target system is on and operating properly.
If the error message persists, check that the logic analyzer pods are
connected to the proper connectors on the preprocessor interface. See
Chapter 1 to determine the proper connections.