Setting item
Item
Transfer to intelligent function
Send data_send area
module
Transfer to CPU
LED lighting status,
communication error status
Transmission control status
Control signal status
Communication result
For receive data
Predefined protocol execution
status
Sending user frame
For user frame confirmation
For modem function
confirmation
For remote password function
Programmable controller CPU
monitoring function
For flash ROM (user frame)
access
Transmission setting, for
mode switching confirmation
Refresh group
Refresh group
Program group No.
Refresh Timing (I/O)
Refresh timing
Description
A refresh setting for the send data storage area.
A refresh setting for confirmation of LED lighting status and
communication error status
A refresh setting for confirmation of transmission control
status
A refresh setting for confirmation of control signal status
A refresh setting for confirmation of communication result
A refresh setting for the receive data storage area
A refresh setting for confirmation of predefined protocol
execution states
A refresh setting for confirmation of user frame being
transmitted
A refresh setting for confirmation of user frame
A refresh setting for confirmation of modem function
A refresh setting for the remote password function
A refresh setting for the programmable controller CPU
monitoring function
A refresh setting for the flash ROM (user frame) access
A refresh setting for confirmation of the transmission setting
and the mode switching
A setting for the refresh group
• At the Execution Time of END Instruction
• At the Execution Time of Specified Program
Designate the number which will be enabled when selecting
'At the Execution Time of Specified Program' for Refresh
group.
Sets the timing to transmit the I/O device data.
• It follows the refresh timing (buffer memory).
Reference
Page 77 Transmitting
Data to Target Device
Page 96 Transmitting
Data to Target Device
Page 441 Checking error
status
Page 447 Current
operation status reading
method
Page 445 RS-232 control
signal status reading method
Page 446 Data
communication status
(transmission sequence
status) reading method
Page 464 ERR LED
turns ON
Page 278 Data
Reception
Page 53 Receiving Data
from Target Device
Page 87 Receiving Data
from Target Device
Page 113 Protocol
Execution Log Storage
Function (for Predefined
Protocol only)
Page 464 ERR LED
turns ON
Page 315 Settings of
send user frames
Page 161 Details of the
buffer memory (for modern
function)
Page 165 Details of
buffer memory (for the
remote password function)
Page 119 USING THE
PROGRAMMABLE
CONTROLLER CPU
MONITORING FUNCTION
Page 377 SWITCHING
THE MODE AFTER
STARTING
26 PARAMETER SETTING
26.2 Module Parameters
26
435

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents