■Program example (When performing the initialization and the line connection from the C24
side simultaneously)
When the data for initialization and connection have been registered with Engineering tool or from the CPU module
Category
Label name
Module label
C24_1.bSts_ModemInitializationCompletion
C24_1.bSts_ConnectionProcessing
C24_1.bSts_Initialization_Connection_AbnormalCompletion
C24_1.bSts_UnitReady
C24_1.bSts_WatchdogTimerError
C24_1.bSet_Req_ModemInitialization
C24_1.bSet_Req_Connection
C24_1.uErrorCode_ModemFunction_D
Label to be defined
Define the global label as shown below.
7 COMMUNICATIONS BY THE MODEM FUNCTION
196
7.4 Startup of the Modem Function
Description
Modem initialization completion
Connection
Initialization/connection abnormal
completion
Module READY
Watchdog timer error
Modem initialization request
Connection request
Modern function error code
Device
X10
X12
X13
X1E
X1F
Y10
Y11
U0\G545