Mitsubishi Electric MELSEC iQ-R Series User Manual page 429

Serial communication module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Item
Receiving area
Receiving buffer memory start address
specification
designation
Receiving buffer memory size
specification
Conversion
ASCII-binary conversion designation
designation
Transparent code
Transparent code
designation_Trans
parent code for
sending
*5
specification (nth)
Additional code
Transparent code
Transparent code
designation_Trans
parent code for
receiving
specification
Additional code
Receiving end
Receive end data quantity designation
specification
Receive end code designation
Protocol execution history specification option
*1 It can be set only on the CH1 side. When the test mode is selected, the communication protocol setting on the CH1 side and the setting
on the CH2 side cannot be configured (will be invalid).
*2 It will be enabled only when "MELSOFT Connection" is selected for the communication protocol setting.
*3 It can be set on the CH2 side only. (Since the linked operation is not available for RJ71C24-R2, it is fixed to "Independent".)
When it is set to "Interlink", the communication protocol setting for the CH2 side cannot be configured.
*4 Set to 8-bit for data communication using MC protocol (Format 5) or Bidirectional protocol.
*5 n: 1 to 10
Description
Set the start address of the area used as the receive area.
Set the size of the area used as the receive area.
Set whether or not data to be communicated to a target
device is communicated with ASCII code.
Set one-byte data for transmission control.
Set '0' to both the transparent code and additional code
when the transparent code for sending is not specified.
Set one-byte data added immediately before the
transparent code and additional code data.
Set the additional code within the range of 01H to FFH
when the transparent code for sending is specified.
Set '0' to both the transparent code and additional code
when it is not specified.
Set one-byte data for transmission control.
Set '0' to both the transparent code and additional code
when the transparent code for receiving is not specified.
Set one-byte data to be deleted at the data reception. (The
immediately succeeding one-byte data is processed for
reception.)
Set the additional code within the range of 01H to FFH
when the transparent code for receiving is specified.
Set '0' to both the transparent code and additional code
when it is not specified.
Set the receive end data quantity.
Set a receive end code.
0D0AH: CR, LF
00H to FFH: Arbitrary receive end code
FFFFH: No designation
Set whether execution logs of all protocol are stored or
whether execution logs of only abnormally completed
protocol are stored.
Setting range
1024 to 6911 (400H to
1AFFH),
9728 to 16383 (2600H to
3FFFH)
(Default (CH1): 1536 (600H))
(Default (CH2): 2560 (A00H))
1 to 6656 (1H to 1A00H)
(Default: 512 (200H))
• Do not convert
• Convert
(Default: Do not convert)
00H to FFH
(Default: 00H: Do not specify
(The transparent code and
the additional code are 0
both.))
00H to FFH
(Default: 00H: Do not specify
(The transparent code and
the additional code are 0
both.))
00H to FFH
(Default: 00H: Do not specify
(The transparent code and
the additional code are 0
both.))
00H to FFH
(Default: 00H: Do not specify
(The transparent code and
the additional code are 0
both.))
1 to 13310
(Default: 511)
0000H to 00FFH, 0D0AH,
FFFFH
(Default: 0D0AH: CR, LF)
• Only protocol that
completed abnormally
• All protocol execution
status and execution
history
(Default: Only protocol that
completed abnormally)
26 PARAMETER SETTING
26.2 Module Parameters
26
427