Operating Conditions: Environment; Ambient Temperature Range; Ambient Temperature Limits - Endress+Hauser Levelflex FMP51 Modbus Technical Information

Guided wave radar
Hide thumbs Also See for Levelflex FMP51 Modbus:
Table of Contents

Advertisement

Levelflex FMP51 Modbus

Ambient temperature range

Ambient temperature limits

Endress+Hauser

Operating conditions: Environment

Measuring device
Local display
Connection cable (for
"Probe Design" = "Sensor
remote")
Remote display FHX50
When operating the device in the open with strong sunlight:
• Mount the device in a shady position.
• Avoid direct sunlight, especially in warmer regions.
• Use a weather protection cover (see accessories).
The following diagrams take into account only function requirements. There may be further
restrictions for certified device versions. Please refere to the separate Safety Instructions.
–40 to +80 °C (–40 to +176 °F)
–20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at
temperatures outside the temperature range.
max. 100 °C (212 °F)
–40 to 80 °C (–40 to 176 °F)