Levelflex FMP51 Modbus
Endress+Hauser
Installation in nozzles ≥ DN300
If installation in ≥ 300mm/12" nozzles is unavoidable, installation must be carried out in accordance
with the following sketch.
1
Lower edge of the nozzle
2
Approx. flush with the lower edge of the nozzle (± 50 mm/2")
3
Plate
4
Pipe  150 to 180 mm (6 to 7 inch)
Nozzle diameter
300 mm (12")
≥ 400 mm (16")
1
2
Plate diameter
280 mm (11")
≥ 350 mm (14")
4
3
A0014199