Diagnóstico de Averías
Problema
Posible(s) Causa(s)
La bomba no se
1. El nivel de agua es muy bajo
enciende o funciona
2. El fusible está quemado o el
cortacircuito se activó
3. El voltaje es muy bajo
4. El motor está dañado
5. El flotante está dañado
6. El impulsor (la bomba está
obstruída con basura)
7. El interruptor está obstruído
8. Nivel de líquido insuficiente
La bomba se
1. El agua se regresa de las tuberías
enciende y se apaga
2. El interruptor/flotante está dañado
constantemente
3. No instaló una válvula de chequeo o
la válvula de chequeo tiene una
fuga
4. La distancia de la descarga es
inferior al mínimo recomendado
por el fabricante
La bomba se apaga y
1. La temperatura del agua es excesiva
se enciende
independientemente
2. El interruptor está dañado u
del interruptor (el
obstruído y por lo tanto la bomba
sistema de protección
funciona al seco
térmica se activa)
3. El voltaje es muy bajo
La bomba hace
1. Los cojinetes están desgastados
mucho ruido o vibra
2. El impulsor está obstruído con
excesivamente
basura o está rota
3. Las tuberías que conectan la bomba
al edificio son muy rígidas o están
muy flojas
La bomba no deja
1. El interruptor flotante está dañado
de funcionar
2. El intyerruptor flotante no se puede
mover libremente
3. Las tuberiás de descarga están
obstruídas
4. Entrada excesiva de agua o la
bomba no es la adecuada para la
aplicación en que se está usando
La bomba funciona
1. El voltaje es muy bajo
pero bombea muy
poca agua o no
2. El impulsor o la tubería de descarga
bombea agua
están obstruídos con basura
3. La bomba tiene alguna pieza
dañada o el impulsor está obstruído
4. La bomba no es la adecuada para la
aplicación en que se está usando
5. La válvula de chequeo está atascada
o instalada incorrectamente
6. La válvula de cierre está cerrada
Acción a Tomar
1. El interruptor no encenderá la bomba a menos que la
bomba esté totalmente sumergida en agua
2. Si el fusible está quemado reemplácelo con uno adecuado o
reconecte el cortacircuito
3. Si el voltaje es inferior al mínimo recomendado, chequée el
alambrado del circuito principal de la propiedad. Si es
adecuado, comuníquese con la compañía de electricidad.
4. Envie el motor al centro de servicio autorizado más cercano
a su domicilio o reemplácelo
5. Reemplace el interruptor flotante
6. Si la propela no gira, destápela y límpiela
7. Coloque el interruptor de modo que se mueva sin
problemas. Reubique la bomba si es necesario
8. Cerciórese de que el nivel de líquido esté por lo menos a 33
cm (13") del fondo de la pileta
1. Instale una válvula de chequeo
2. Reemplace el interruptor flotante
3. Desconecte la válvula de chequeo y revísela a ver si está
bien instalada y funcionando adecuadamente
4. Haga los cálculos una vez más para cerciorarse de que esté
usando una bomba adecuada
1. La bomba no se debe usar para bombear agua a más de
44°C (120° F).
2. Reemplace o reubique la bomba
La bomba puede comenzar a
PRECAUCION
!
funcionar sin previo aviso.
Desconéctela del tomacorrientes antes de darle servicio
3. Si el voltaje es inferior al mínimo recomendado, chequée el
alambrado del circuito principal de la propiedad. Si es
adecuado, comuníquese con la compañía de electricidad
1. Cambie la bomba
2. Destape la unidad, limpie el impulsor y/o reemplácelo si está
roto
3. Reemplace una porción de la tubería de descarga con un
conector flexible
1. Reemplace el interruptor flotante
2. Reubique la bomba o limpie la pileta según sea necesario
para que el flotante se mueva sin problemas
3. Desconecte la bomba y limpie la bomba y las tuberías
4. Haga los cálculos una vez más para cerciorarse de que esté
usando una bomba adecuada
1. Si el voltaje es inferior al mínimo recomendado, chequée el
alambrado del circuito principal de la propiedad. Si es
adecuado, comuníquese con la compañía de electricidad.
2. Desconecte el impulsor, límpielo y cerciórese de que esté
bien instalado
3. Reemplace las piezas dañadas o toda la bomba. Si es
necesario limpie las piezas que estén sucias
4. Haga los cálculos una vez más para cerciorarse de que esté
usando una bomba adecuada
5. Desconecte la válvula de chequeo y revísela a ver si está
bien instalada y funcionando adecuadamente
6. Abra la válvula
14 Sp
Operating Instructions
General Safety
3. Drill a 1/16" hole in the discharge
pipe approximately 1" to 2" above
Information
(Continued)
the pump discharge when a check
valve is used. The hole prevents air
DANGER
!
locking of the pump at the initial
Do not walk on wet area
start-up and if it should lose prime.
until all power has been
4. A gate valve should be installed in
turned off. If the shut-off
the system after the check valve.
box is in basement, call the
This gate valve should be a full port
electric company to shut-off service to
the house, or call the local fire
valve which will pass 2" solids or as
department for instructions. Remove
required by state and local codes.
pump and repair or replace. Failure to
This gate valve permits removal of
follow this warning can result in fatal
the pump and/or check valve for
electrical shock.
servicing.
5. A union should be installed

Installation

between the check valve and the
In any installation
pump so the pump can be removed
NOTICE
where property
with least disturbance of the piping.
damage and/or personal injury might
6. The pump has a detachable tether
result from an inoperative or leaking
pump due to power outages, discharge
switch with a piggyback plug (see
line blockage or any other reason, use a
figure 3). The length of the tether
backup system(s).
(distance of cord from float to
1. Thread the discharge pipe or pipe
clamp) should not be set shorter
nipple into the discharge
than 3-1/4 inches and should not be
connection.
used in a basin smaller than 14
2. If a check valve is used in a solids
inches in diameter. If using a
handling system mount the check
differential other than the factory
valve in a horizontal position or at a
setting, be sure when the pump
45° angle with the valve pivot on
shuts off at least 4" of fluid is left in
top. In a vertical position, solids will
the basin so the impeller remains
tend to lodge on the valve flapper
submerged.
and can prevent it from opening.
7. When a tether switch is used, rigid
discharge pipe is required. If the
pump is allowed to move, the tether
Check valve 45
o
switch could be restricted by the
basin wall, preventing the pump
from operating.
CAUTION
!
for service, always disconnect electrical
power to pump and control switch. For
any work on pump or switch, ALWAYS
unplug the power cord. Do not just turn
off circuit breaker or unscrew fuse.
Vent

Maintenance

WARNING
!
Gasket
Inlet
unplugged before attempting to service
or remove any component. This pump is
assembled in the factory using special
equipment; therefore only authorized
service dealers or qualified electricians
1/2"
should attempt to repair this unit.
Min.
Improper repair can cause an electrical
Clearance
shock hazard.
NOTICE
under pressure because of heat. Let the
Basin
pump cool for a minimum of two hours
Figure 3 - Prefabricated Basins
before servicing this unit.
1. Disassembly of the motor prior to
expiration of warranty will void the
warranty. It might also cause
internal leakage and damage to the
unit. If repairs are required, return
the pump to the dealer from whom
it was purchased or call 1-800-237-
0987.
2. After the basin cover is removed
and necessary discharge piping
disconnected, lift pump from basin.
3. Pump should be checked on a
regular basis for proper operation.
If anything has changed since unit
was new, the unit should be
removed and replaced. Only
qualified electricians or service peo-
ple should attempt to repair this
unit. Improper repair and/or
assembly can cause an electrical
shock hazard.
4. Place the pump in a suitable area
where it can be cleaned thoroughly.
Remove all scale and deposits on
pump.
5. Submerge the complete pump in a
disinfectant solution (10% chlorine
bleach solution) for at least one
hour before handling the pump.
6. Clean all dirt and deposits from the
pump float. Make sure float moves
freely after cleaning.
7. Clean all dirt and deposits away
from pump inlet and volute.
This pump contains
WARNING
!
dielectric motor oil
for lubrication and motor heat transfer.
This oil can be harmful to the
Before removing
environment. Check state
pump from basin
environmental laws before disposing of
this oil. This oil can be harmful to
aquatic life so consideration should be
exercised in the application of this
pump.
Make certain that
the pump is
The pump contains
oil that may be
www.waynepumps.com
3