Description
The Wayne pumps are general use
centrifugal water pumps. The pump is
®
equipped with a Viton
seal assembly
that is also compatible with many
agricultural chemicals.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates an
imminently hazardous
situation which, if not avoided, WILL
result in death or serious injury.
Warning indicates a
potentially hazardous
situation which, if not avoided, COULD
result in death or serious injury.
Caution indicates a
potentially minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
General Safety
Information
CALIFORNIA PROPOSITION 65
This product or its
power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm. Wash
hands after handling.
1. Know the pump application,
limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them could
cause serious bodily injury and/or
property damage.
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2010 WAYNE Pumps
Engine Driven
Centrifugal Pump
an enclosed area. Exhaust
gases contain deadly
poisonous carbon monoxide,
which has no odor or taste.
flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do not use in
flammable and/or explosive atmospheres.
Pump should only be used with liquids
compatible with pump component materials.
Failure to follow this warning can result in
personal injury and/or property damage.
2. Observe all safety precautions for the
handling of the fuel.
hot engine. Fuel spilled on a
hot engine could result in a
fire or explosion. Do not
refuel a running engine.
3. Pump should be located and should
rest on a level solid foundation. Do
not suspend pump by means of the
discharge pipe.
doesn't fall over.
4. Do not use torches or apply excessive
heat, fire or flames to this pump as an
explosion may result.
5. Before working on the unit, insulate
the wire from the spark plug, by
disconnecting the spark plug wire from
the spark plug.
MUST be protected against below freezing
temperature. Failure to do so could cause
serious damage and voids the warranty.
6. Do not run pump dry. Water is
required to lubricate the shaft seal.
Attach it to this manual or fi le it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
Never run
7. Pumping chemicals or corrosive liquids
engine in
8. Personal Safety:
Do not use
to pump
9. This pump is designed for non-abrasive
Do not
refuel a
Installation
This pump is designed to be self-priming
when installed and operated as specified
below.
1. The pump should be placed as close as
Be sure pump is on
secure footing so it
Complete pump and
piping system
Figure 1
GPS400
Need
Assistance?
Call Us First!
1-800-237-0987
with this pump may shorten the life of
the pump and may be hazardous to the
operator.
a. Wear safety glasses at all times when
working with pumps.
b. Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c. Keep visitors at a safe distance from
the work area.
d. Make workshop child-proof with
padlocks, master switches, and by
removing starter keys.
fluid transfer; do not use as a trash
pump. Always use a suction strainer with
this pump to filter abrasive material.
Abrasive materials such as sand and
gravel will shorten the life of the pump.
possible to the water being pumped.
A pump with 20 foot suction lift will
not remove water as quickly as a pump
with 5 foot suction lift (Figure 1).
20 Ft. Suction Lift
5 Ft.
Suction
Lift