Procedure
4. If the motor emits a high frequency noise but the shaft is not
(cont'd)
5. After successfully establishing motion, the system can be
Note: A bus capacitor should be connected to the 6415 power
input. The bus capacitor should be connected using a twisted pair
cable no longer than three feet in length. For maximum voltage
and current, a 100 volt, 5 A rms (120 Hz ripple current rating),
6000 uf capacitor is recommended.
Getting help
If you need further assistance with your installation, please contact
your local distributor.
3 - 22
rotating, stop the motor. Lower the RUN SPEED by turning
the RUN SPEED potentiometer CCW. Increase the ACCEL
RAMP by turning the ACCEL RAMP potentiometer CW.
powered down and connected to a load.
6415 Installation and Hardware Reference Manual - Rev E