Pacific Scientific 6415 Installation & Hardware Reference Manual page 28

Oscillator/drive
Table of Contents

Advertisement

Cabling diagram
- J3 motor
To
Motor
Note: The colors in the diagram follow the Pacific Scientific
stepper motor cable color code.
Procedure
1. Strip the wires to 0.27 in (7mm).
2. Attach wires to connector as indicated in the diagram.
Note: Make sure the screws on the PCD connector are tightened
down firmly on the wiring.
Do not solder the tips of the cables before insertion into the
connector. Solder can contract and cause a loose connection
over time.
2 - 12
Motor Case
Gnd (Green)
.27 in
(7 mm)
B (Yellow)
.27 in
(7 mm)
B (Red)
.27 in
(7 mm)
A (Orange)
.27 in
(7 mm)
A (Black)
.27 in
(7 mm)
Caution
6415 Installation and Hardware Reference Manual - Rev E
5
To
4
Drive
3
2
1