COMMISSIONING
4.1

Preliminary checks

First ignition is carried out by competent personnel from an authorised
Technical Assistance Service Beretta.
Before starting up the boiler, check:
- that the data of the supply networks (electricity, water, gas) correspond
to the label data
-
working correctly
- that conditions for regular maintenance are guaranteed if the boiler is
placed inside or between items of furniture
- the seal of the fuel adduction system
-
-
the boiler, and that it has all the safety and control devices required by
current regulations
- that the circulator rotates freely because, especially after long periods
of inactivity, deposits and/or debris can prevent free rotation.
paragraph "3.12 Manual reset of the boiler"
4.2
Programming the boiler
- Position the system's master switch to the "on" position.
If necessary, the interface automatically goes to the clock menu. On the
main screen the icons
,
sec ON, 0.5 sec OFF.
To set the time and day follow the following instructions:
set the hour with the
and
set the minutes with the
set the day of the week with the
Enter
then returns to the main screen
press
.
accessing the TIME parameter in the SETTING menu, or by pressing the
A+C keys for at least 2sec.
+
A
Each time that the boiler is powered a vent cycle is carried out lasting 4 min.
,
and
and
and
arrows. The segment in
+
C
RESET
MENU
Set the boiler to OFF by pressing
See the
series of parameters that can be programmed to allow you to personalise
the operation of the boiler based on the type of system.
Set the parameters according to the desired operating modes.
4.3
If the heating system is managed by a room thermostat, and therefore
without programming timing, the programming timing on the boiler interface
To access the programming timing menu press the keys B+D for at least
2sec.
B
A
A
,
1-2-3-4-5-6-7 programming the individual days
1-5 programming from Monday to Friday
6-7 programming from Saturday to Sunday
1-7 programming the entire week
With the
the programming of the time bands, with the
With the
key you exit without saving the selections.
Setting the Time Bands
- The display shows TIME ON, press
- The display shows TIME OFF, press
,
.
+
+
RESET
MENU
arrows select the day or the pre-selected group of days:
to set the ignition time, with
.
to set the switching off time, with
.
ENGLISH
D
Enter
key you exit the
,
15