SETTINGS MENU TREE STRUCTURE

Below is a list of the parameters that can be programmed; if the adjustment board does not support the relative function, the interface
returns an error message:
Menu
Parameter
SETTINGS
TIME
TIME PROGRAMM
COMB
GAS TYPE
BOYLER TYPE
COMBUSTION OFFSET
CONF
HYDRAULIC CONFIGURATION
WATER TRANSDUCER
AUTO WATER FILL ENABLE
BEGIN SYSTEM FILLING
AIR PURGING CYCLE
MIN
MAX
MAX_CH
RANGE RATED
DO_AUX1
EXHAUST PROBE RESET
CH
HYST ON HIGH TEMP
HYST OFF HIGH TEMP
HYST ON LOW TEMP
HYST OFF LOW TEMP
PUMP CONTROL TYPE
CH POSTCIRC
LOW NOISE
SCREED HEATING
ANTI CYCLE FUNCTION
RESET CH TIMERS
MAIN ZONE ACTUATION TYPE
MAIN ZONE ADDR
MAIN ZONE HYDRAULIC CONF
MAIN ZONE TYPE
MAX CH SET
MIN CH SET
OTR
12
Value
0 / 1
1/2/3
0 / 1 / 2
0 / 1/ / 2 / 3 / 4
0 / 1
0 / 1
NOT AVAILABLE ON THIS MODEL
0 / 1
MIN - MAX
MIN - MAX_CH
0 / 1 / 2
0 / 1
2 - 10
2 - 10
2 - 10
2 - 10
0 - 100
NOT AVAILABLE ON THIS MODEL
NOT AVAILABLE ON THIS MODEL
0 / 1
0 - 20min
0 / 1
0 / 1
1 - 6
0 / 1
0 / 1
AT: MIN CH SET - 80.5
BT: MIN CH SET - 45.0
AT: 40 - MAX CH SET
BT: 20 - MAX CH SET
0 (default) / 1
Level
Value set
password
in the factory
USER
USER
INSTALLER
0
1 (25k W)
SERVICE
2 (30k W)
3 (35k W)
SERVICE
INSTALLER
1
SERVICE
1
SERVICE
0
SERVICE
1
see technical data
INSTALLER
table
see technical data
INSTALLER
table
see technical data
INSTALLER
table
see technical data
INSTALLER
table
INSTALLER
0
INSTALLER
0
SERVICE
5
SERVICE
5
SERVICE
3
SERVICE
3
INSTALLER
85
INSTALLER
0
INSTALLER
3min
INSTALLER
0
INSTALLER
0
INSTALLER
3
INSTALLER
0
INSTALLER
0
80.5
INSTALLER
INSTALLER
40
INSTALLER
0
-
-
Personalised