Step 4 - Wiring The Fan - Hunter Carera Installation And Operation Manual

Table of Contents

Advertisement

®

STEP 4 - WIRING THE FAN

WARNING
• To avoid possible electrical
shock, before wiring fan,
disconnect power by turn-
ing off the circuit breakers
both to the outlet box and
to its associated wall switch
location. If you cannot lock
the circuit breakers in the
off position, securely fasten
a prominent warning de-
vice, such as a tag, to the
service panel.
• All wiring must be in accor-
dance with national and
local electrical codes. If you
are unfamiliar with wiring,
you should use a qualified
electrician.
• Failure to complete the sub
steps 1-3 below could result
in the fan falling.
14
WARNING
To reduce the risk of fire, elec-
trical shock, or motor damage,
do not lift or carry the fan by
the lead wires.
1. Disconnect the power by turning
off the circuit breakers to the out-
let box and associated wall switch
location.
2. Carefully lift the fan assembly and
position the hanger bracket with
the ceiling plate as shown in Fig-
ure 4a.
3. Rotate the hanger bracket until
the three tabs on the hanger
bracket are fully engaged in the
three slots in the ceiling plate.
See Figure 4b. Being careful to
not allow the hanger bracket to
rotate, temporarly install one of
Slot in Ceiling
Plate (3)
Ceiling Plate
Hanger
Bracket
Figure 4a - Aligning the Hanger
Bracket with the Ceiling Plate
Ceiling Plate
#6-32 x
3/8"
Figure 4b - Temporary installation of
one #6-32 x 3/8" screw.
41419-01
Tab (3)
10/29/2002