Hunter ceiling fan Instruction Manual

Ceiling fan
Hide thumbs Also See for ceiling fan:

Advertisement

Table of Contents
Congratulations on purchasing
your new Hunter® ceiling fan! It will
provide comfort and performance
in your home or office for many
years. This installation and operation
manual contains complete
instructions for installing and
operating your fan.
We are proud of our work and
appreciate the opportunity to
supply you with the best ceiling fan
available anywhere in the world.
To register your fan, please visit:
www.HunterFan.com/register
Save your receipt for proof of purchase.
Blades
12
What to Expect with
Your Installation
7 feet
Preparation
Switch Housing
Light Kit
13
M0019-01 • 04/19/13 • © Hunter Fan Company
Tools Needed
30 inches
2
Ladder
3
Downrod
6
7
Remote Control
14
16
1
www.HunterFan.com
Mounting Options
Ceiling Bracket
4
Wiring
10
Operation,
Maintenance & Cleaning
Troubleshooting
?
?
17
1.888.830.1326
5
Canopy
11
?
19

Advertisement

Table of Contents
loading

Summary of Contents for Hunter ceiling fan

  • Page 1 What to Expect with Your Installation Tools Needed Mounting Options Ceiling Bracket your new Hunter® ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation 30 inches manual contains complete...
  • Page 2: What To Expect With Your Installation

    - To reduce the risk of fire, electrical shock, or motor You may need a Standard Downrod damage, use only Hunter Solid State Speed Controls. friend to help you. for ceilings 8-10 feet high w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan.
  • Page 3: Tools Needed

    Tools Needed www.HunterFan.com 1.888.830.1326 Pliers Wire Strippers Screwdrivers Ladder Power Drill 9/64” Drill Bit (optional) (optional) If mounting to a support structure, you will also need these tools. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 4: Mounting Options

    You need BOTH You need ONLY a Longer a Longer Downrod & Downrod an Angled Mounting Kit *most common M0019-01 • 04/19/13 • © Hunter Fan Company M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 5: Ceiling Bracket

    To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet Refer to warning w.1 on pg. 2 box associated with the wall switch location. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 6 Save the screws. They will be next couple of steps. needed for blade iron installation. Note: Some fans will have a shipping ring instead of shipping blocks. Please remove the ring and save the screws. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 7 Steps 1-5 to remove standard downrod pipe Longer Downrod for angled ceilings or ceilings 10’ or higher Shorter Downrod for fans installed close to ceiling Steps 6-10 to reassemble with new pipe M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 8 4-5 full turns) until it stops. with pliers. DO NOT can be inserted. from the top of the downrod. HAND TIGHTEN. 8” 3/8” If the setscrew is not tightened securely, the fan may fall. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 9 Put the wires and downrod through the canopy. Let the canopy sit loosely on top CANOPY OR WIRES. Place the downrod of the fan. ball into the slot in the ceiling bracket. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 10 Spread the wires apart, with the grounded wires on one side of Refer to CAUTION c.1 on pg. 2 the outlet box and the ungrounded wires on the other side of the outlet box. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 11 Insert the two canopy screws lifted into place, the canopy fits into the screw holes are aligned. found in the hardware bag. the hanging bracket as shown. Note: Fan style may vary. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 12 Your blades are shielded with Dust Armor® which is a nanotechnology coating that repels dust. For cleaning the fan, use soft brushes or cloths to prevent scratching. Cleaning agents may damage the finishes. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 13: Switch Housing

    Make sure the upper switch housing is securely attached to the mounting plate. Failure to properly secure all 3 assembly screws could result in the switch housing fixture falling. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 14: Light Kit

    Failure to properly secure all three Go to www.HunterFan.com/FAQs and click assembly screws could result in the light fixture falling. “How do I install my fan without the light kit?” M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 15: Operation Instructions

    Note: Globe style and number of Note: In compliance with US federal energy regulations, this ceiling fan lights may vary. contains a device that restricts its light output. Exceeding the wattage limit marked on the MAX wattage sticker affixed to the light socket(s) may result in fire hazard or improper operation.
  • Page 16: Remote Control

    If it does not, turn off power to your fan, wait 1 minute then try again. If using the transmitter with multiple fans, repeat this process for each fan. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 17 Insert and tighten the screws. Do not over tighten. Note: For rocker-style cover plates, break off the tabs by pushing outward. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 18 Carefully remove the globe. Unscrew bulbs and replace with bulbs of same type and wattage. Reinstall the globe assembly. For questions regarding removing a light kit, call customer service 1-888-830-1326. M0019-01 • 04/19/13 • © Hunter Fan Company...
  • Page 19: Troubleshooting

    • Make sure the battery is on page 10. installed correctly. • Check the plug connection in • Install a fresh battery. the switch housing. Transmitter only works when held at close range • Change battery. M0019-01 • 04/19/13 • © Hunter Fan Company...

This manual is also suitable for:

Ceiling fan

Table of Contents