the three #6-32 x 3/8" screws
through the hole in the ceiling
plate and into the threaded hole
in the hanger bracket to prevent
the hanger bracket from rotat-
ing. See figure 4b.
CONNECTING FAN TO
ELECTRICAL SOURCE
Use Figures 4c, 4d and 4e for refer-
ence in making the following elec-
trical connections.
1. Connect the supply mains to the
terminal block mounted on the
hanger bracket.
2. Connect the safety earth (green/
yellow) wire to the terminal
marked
.
3. Connect the blue neutral wire to
the terminal marked "N."
4. Connect the brown line wire to
the terminal marked "L."
41419-01
10/29/2002
Note: An additional "L" termi-
nal is provided for separate con-
trol of the light kit, if a separate
supply line is provided for that
purpose.
5. Connect the motor leads to the
harness assembly attached to the
hanger bracket and terminal
block. See Figure 4c, 4d and 4e.
Note: Unless there is a separate
line for the light kit, connect the
black/white wire and the brown
wire from the motor housing to
the same "L" terminal.
CAUTION
Be sure no bare wire or wire
strands are visible after making
connections.
®
continued