STARTING UNIT - STANDBY OPERATION

Make sure the power plug is clean and dry before connecting to any electrical outlet / receptacle.
Do not connect to any electrical outlet without checking that it meets the 380/3/50 and 16 Amp elec-
trical requirements of the unit.
1. Ensure the Engine/Standby switch is in the
STANDBY position and the Start/Run--Off
switch is in the OFF position
3. Place the START / RUN - OFF switch
(SROS) in the START / RUN position.
The unit is equipped with automatic phase re-
versal which insures that the electric motors
will run in the correct direction.
For safe, reliable operation in Standby Operation,
it is important to consider the following guidelines:
 NEVER connect the unit to a high voltage power
source with the SROS in the START / RUN posi-
tion.
62-61753-21
- -20.0
NOTE
WARNING
WARNING
2. Ensure the external power circuit breaker is off, con-
nect standby cable to unit and then turn the external
power circuit breaker on.
+34.5° F
4. The unit will then enter pretest, perform preset
I
START /RUN
(refer to section 3.3) and start automatically.
0
OFF
 The power supply cable and circuit breaker must
comply with local electrical code and unit specifica-
tions. Refer to Section 2.11.
 The power supply cable must be equipped with a
ground connection.
 Repairs or maintenance to the supply voltage cir-
cuit should only be performed by licensed / author-
ized personnel.