Starting The Unit -- Standby Operation - Carrier Transicold Supra 550 Operator's Manual

Carrier transicold truck refrigeration unit
Table of Contents

Advertisement

S
TARTING THE UNIT - -
Make sure the power plug is clean and dry before con-
necting to any power source.
Do not attempt to connect or remove power plug or
perform service and/or maintenance before ensuring
the unit RUN/STOP Switch is in the STOP position and
the I/O switch is in the "O" position.
-20
FUNCTION
I
O
1. Place the unit RUN/STOP switch in the
"STOP" position and the I/O switch in the "O"
position.
2. Connect unit to appropriate power source.
(See table on page 39)
3. Place the unit RUN/STOP switch in the
"RUN" position and the I/O switch in the "I"
position.
Under normal circumstances this is all that is required to run the unit
in standby power. The unit will then perform a complete diagnostic
check on the microprocessor controller and start automatically.
Complete the Pre-Trip Inspection described in the previous section.
S
TANDBY
35° F
SETPOINT
BOX TEMPERATURE
CITY
ROAD
SPEED
O
PERATION
WARNING
ENTER
MAN
BUZZER OFF
DEFROST
4. Press Standby key.
7
ALARM/FAULT
i
UNIT DATA
AUTO START/STOP
PRETRIP
STANDBY